CONTROL PANEL AND ICONS

icon
meaning
• Indicates the presence of an alarm. The machine will turn off.
• This indicates the system pressure detected by the machine.
• It indicates the pump operation: Off = pump OFF; ON = pump on
Flashing ling = the safety device is active (H2O temperature > 85°C)
• indicates the contact of the external additional thermostat
contact closed: the contact of the additional external thermostat is closed.
contact open: the contact of the additional external thermostat is open.
• Indicates the operating status of the machine, with manual operation or weekly programming.
Hand icon: the weekly programming function is off (manual management)
Chrono icon: activates the weekly programming function
TeMperATure
h20 BoiLer
By briefly pressing
appear additional information, such as:
DeTecTeD pressure in The
BoiLer
18
DispLAying The vArious
TexT MessAges
DAy, DATe, TiMe, yeAr
ENGLISH
AcTuAL power
power seT
chrono AcTive
or MAnuAL MoDe
sTATus of The conTAcT.
exTernAL
sTAnD-By funcTion
puMp, if AcTive