Display; Alarms - Extraflame HP15 EVO User Manual

Pellet boilers
Table of Contents

Advertisement

DISPLAY

Off
Generator off
START
Start phase in progress
PELLET LOADING
Continuous loading of pellets during ignition in progress
IGNITION
Ignition phase in progress
BURNING
Start-up phase in progress
WORK
Normal operation phase in progress
MODULATION
The generator is operating at minimum
BURN POT
Burning pot cleaning in progress
CLEANING
*BURN POT CLEANING
Burning pot cleaning in progress – for insufficient depression
DEPRESSION
fINAL CLEANING
Final cleaning in progress
STAND-BY
Generator off waiting to turn back on because of the external thermostat
There is an attempt to turn the generator back on when it has just been turned off. When the generator is
COOLING STAND BY
turned off, it is necessary to wait for the fumes motor to turn off completely, then clean the burning pot.
Only after performing these operations will it be possible to turn the generator back on.
HOff
Generator off for water temperature above the set value.
*T-AMB
Display ambient temperature (in the models where available).
*T - Off
Generator off waiting to be turned back on because of all the requirements met.
The generator is cooling down after a power failure.
BLACK OUT STAND BY
After cooling down, it will turn back on automatically.
The anti-freezing function is in progress because t° H2O is below the default threshold. The pump
ANTIfREEZE
will be activated until the water has reached the default parameter +2°C
The pump anti-block function is in progress (only if the generator has been Off for at least 96 hours).
ANTILOCKING
The pump will be activated for the time pre-set by the manufacturer, so as to prevent the same from blocking.
AUTO BLOW
The automatic blow is active
*CLEANING SPRINGS
The cleaning of the exchanger is blocked
BLOCKED
DISPLAY
Indicates the presence of an alarm.
fUMES fAILURE
Fumes motor fault
* on models where available.
DISPLAY

ALARMS

EXPLANATION
ENGLISH
REASON
On: indicates the presence of an alarm
Flashing: indicates the deactivation of the depression sensor.
The alarm can be reset only if the fumes motor has been off for 15
minutes from when the alarm appeared, by pressing key 1/
Contact customer service
SOLUTION
for 3 seconds.