Operation And Logics - Extraflame HP15 EVO User Manual

Pellet boilers
Table of Contents

Advertisement

OPERATION AND LOgICS

IgNITION
Once you have checked the "basic instructions" listed above, press the
15 minutes are available for the ignition phase. After ignition and having reached the control temperature, the generator stops the ignition
phase and passes to sTArTing.
STARTINg
During the start-up phase, the generator stabilises combustion, increasing it progressively, then switching to worK mode.
WORk
During the work phase, the generator reaches the set power; see following item.
ADjUSTMENT SET POWER
Set the operating power from 1 to 5.
Power 1 = minimum level - Power 5 = maximum level.
ADjUSTMENT TEMPERATURE SET H2O
Set the boiler temperature between 65 - 80°C .
PUMP OPERATION
The pump activates water circulation when the in the generator the t° of the water reaches 60°C. As the pump always functions above 60°, an
always open heating area is recommended to make product functioning increasingly uniform, preventing overheating blocks. Normally this
area is defined "safety zone".
BURN POT CLEANINg
At pre-set intervals the generator performs the brazier cleaning, switching the machine off.
When the cleaning phase is finished, the generator will re-start automatically and continue its work back to the power level selected.
MODULATION and H-Off
As the water temperature approaches the set point, the boiler starts to modulate automatically bringing itself to the minimum power.
if the temperature increases beyond the set point, it will automatically switch off indicating H-Off and will automatically go back on when
the temperature drops below the set point.
SWITCH-Off
Press key 1 for three seconds.
When the operation has been performed, the appliance automatically enters the switch- off phase, blocking the supply of pellets.
The flue gas exhaust motor will remain on until the generator temperature has dropped below the factory parameters.
RE-IgNITION
The genertor can be re-ignited both automatically or manually, when the cooling cycle conditions and the preset timer have been satisfied.
DO NOT USE ANY INfLAMMABLE LIqUIDS fOR IgNITION!
DO NOT ALLOW THE BAg Of PELLETS TO COME INTO CONTACT WITH THE HOT gENERATOR!
IN THE EvENT Of CONTINUOUS NO IgNITION, CONTACT AN AUTHORISED TECHNICIAN.
for more than two seconds to turn on the generator.
ENGLISH
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hp22 evoHp30 evo

Table of Contents