fUMES PROBE
Fumes probe fault.
HOT EXHAUST
High fume temperature
The door is not closed properly.
The ash drawer is not closed properly.
ALL CLEAN CHECK UP
The combustion chamber is dirty.
The fume exhaust duct is blocked.
The pellet hopper is empty.
NO IGNITION
Pellet loading value inappropriate.
Thermostatic bulbs tripped.
BLACK OUT
No power during the ignition phase
NO IGNITION
The pellet hopper is empty.
NO PELLET
Pellet not loading.
The gearbox is not loading pellets.
The door is not closed properly.
The ash drawer is not closed properly.
DEPRESSION ALARM
The combustion chamber is dirty.
The fume exhaust duct is blocked/dirty.
Flow sensor faulty.
DAMAGE DEPR SENSOR
Sensor disconnected
Air in the system
WATER OVERTEMP
Circulation inappropriate
The automatic cleaning of the burning pot is
blocked.
* TRAPDOOR BLOCKED
Burning pot dirty/blocked
The door is not closed properly.
MIN H2O PRESSURE
The system pressure detected by the pressure
ALARM
switch is too low.
PROBE H2O
H2O probe fault
MAX H2O PRESSURE
The water pressure is above the maximum
ALARM
threshold
* PRESSURE SENSOR
Pressure differential sensor faulty, disconnected or
DAMAGED
broken
* AUGER CONTROL
Pellet loading not working correctly
ALARM
* AUGER BLOCKED
Pellet motor not working correctly
* DHW PROBE
Boiler probe fault.
* PUffER TANK PROBE
Boiler probe fault.
The pellet hopper is empty.
The door is not closed properly.
* EMPTY HOPPER
The ash drawer is not closed properly.
The combustion chamber is dirty.
The fume exhaust duct is blocked..
* where available.
32
Contact customer service
Check the pellet loading (see "Easy Setup"); if the problem persists, contact a
qualified technician
Check the hermetic closure of the door.
Check the hermetic closure of the ash drawer.
Make sure that the fumes duct, the primary air duct sensor and the combustion
chamber are clean.
Check for the presence of pellets inside the hopper.
Adjust the pellet flow (see "Easy Setup").
Check the procedures described in the chapter "Ignition".
Check the bulb thermostats (see the chapter "Reset")
Turn the stove OFF by pressing key 1 and repeat the procedures described in the
chapter "Ignition".
Check for the presence of pellets inside the hopper.
Adjust the pellet flow (see "Easy Setup").
Check the hermetic closure of the door.
Check the hermetic closure of the ash drawer.
Make sure that the fumes duct and the combustion chamber are clean.
Contact customer service
Possible air in the system, bleed the system.
No suitable circulation,.
No safety area or not suitable.
The water inside the stove is above 95°C.
Possible pump fault.
If the problem persists, the reset operations must be performed by an authorised
technician.
Check that the door is closed properly.
Check that the burning pot is free and clean.
The automatic cleaning of the burning pot is blocked.
If the problem persists, contact customer service
Possible air in the system, bleed the system.
Possible lack of water or leaks due to faults in some components of the system.
If the problem persists, contact customer service
Contact customer service
Possible air in the system, bleed the system.
Make sure that the expansion vessels are not damaged or too small
Make sure that the system (cold) is loaded at the right pressure
If the problem persists, contact customer service
Contact customer service
Contact customer service
Contact customer service
Contact customer service
Contact customer service
Check for the presence of pellets inside the hopper.
Check the hermetic closure of the door.
Check the hermetic closure of the ash drawer.
Make sure that the fumes duct, the primary air duct sensor and the combustion
chamber are clean.
Contact customer service