  • Page 1 PELLET BOILERS USER MANUAL HP15 EVO - HP22 EVO - HP30 EVO MADE ITALY design & production 004276734 - Rev 005...
  • Page 3: Table Of Contents

    ATTENTION SURfACES CAN bECOmE VERy HOT! ALWAyS USE pROTECTIVE GLOVES! During combustion, thermal energy is released that significantly increases the heat of surfaces, doors, handles, controls, glass, exhaust pipes, and even the front of the appliance. Avoid contact with those elements if not wearing protective clothing (protective gloves included).
  • Page 4: English

    TECHNICAL CHARACTERISTICS CHARACTERISTICS HP 15 EVO HP 22 EVO HP 30 EVO Weight Height 1304 1304 1408 Width Depth Diameter of fume outlet pipe Diameter of fume intake pipe Min global thermal input 10,1 Min useful thermal input Max global thermal input 16,7 24,5 33,9...
  • Page 5: Identification Of Components

    Boiler supply/output Door Boiler return/input Power socket for electrical cable Safety thermostat (manual reset) 100°C Safety thermostat (manual reset) 85°C Combustion fume outlet pipe Air intake pipe for combustion Main start-up switch Serial port HP30EVo HP15 EVo - HP22 EVo ENGLISH...
  • Page 6: Introduction

    INTROdUCTION The boilers produced in our factory are built with attention to the individual components so as to protect both the user and the installer from any accidents. It is therefore recommended that after any intervention on the product, the authorised staff pay particular attention to the electric connections, especially the stripped parts of the wires.
  • Page 7: Recommended Distances For The Boiler Compartment

    Š Do not leave the packaging elements within reach of children or unassisted disabled persons. Š The hearth door must always be closed during normal functioning of the product. Š Avoid direct contact with parts of the appliance that tend to heat up during functioning. Š...
  • Page 8: Warnings

    We thank you for having chosen our company; our product is a great heating solution developed from the most advanced technology with top quality machining and modern design, aimed at making you enjoy the fantastic sensation that the heat of a flame gives, in complete safety. Warnings This instructions manual is an integral part of the product: make sure that it always accompanies the appliance, even if transferred to another owner...
  • Page 9 CHILDREN) WITH REDUCED PHYSICAL, SENSORY AND MENTAL CAPACITIES OR WHO ARE UNSKILLED PERSONS, UNLESS THEY ARE SUPERVISED AND TRAINED REGARDING USE OF THE APPLIANCE BY A PERSON RESPONSIBLE FOR THEIR SAFETY. Š THE CLEANING AND MAINTENANCE REQUIRED BY THE USER MUST NOT BE PERFORMED BY CHILDREN WITHOUT SUPERVISION.
  • Page 10: Routine Maintenance

    SYSTEMS. Š IN THE EVENT THE FLUE CATCHES FIRE, USE SUITABLE SYSTEMS FOR SUFFOCATING THE FLAMES OR REQUEST HELP FROM THE FIRE BRIGADE. Š THIS APPLIANCE MUST NOT BE USED TO BURN WASTE Š DO NOT USE ANY FLAMMABLE LIQUIDS FOR IGNITION Š...
  • Page 11: Hydraulic System

    Standards in force, national, regional and municipal, as well as these instructions. For Italy, installation must be carried out by professionally qualified staff (Ministerial Decree dated 22.01.08 n°37). Extraflame S.p.A. declines all responsibility for damage to objects and/or persons caused by the system. TYPE OF SYSTEM Š...
  • Page 12: Anti-Condensation Device (Mandatory)

    DISTANCES OF SAFETY DEVICES ACCORDINg TO THE STANDARD The temperature safety sensors must be in place on the machine at a distance no greater than 30 cm from the flow connection. Whenever the generators lack a device, those missing can be installed on the generator flow pipe, within a distance no greater than 1 m from the machine. COMMISSIONINg CHECkS Before connecting the boiler: a) wash all system piping thoroughly in order to remove any residues which might compromise the correct functioning of certain system...
  • Page 13: Positioning

    85°c 100°c 85°c 100°c FEAtUREs Hp15 EVo Hp22 EVo Hp30EVo Water content of the thermo-product heat exchanger (l) Volume of expansion vessel integrated in the thermo-product (l) 3 bar safety valve integrated in the thermo-product...
  • Page 14: Installation

    InstallatIOn general The flue gas exhaust and hydraulic connections must be carried out by qualified personnel who must issue installation conformity documentation compliant with national standards. The installer must provide the owner or person acting for him, according to the legislation in force, with the declaration of conformity, supplied with: 1) the use and maintenance manual of the appliance and of the system components (such as for example, the smoke ducts, chimney, etc.);...
  • Page 15 In the presence of type B gas appliances with intermittent operation not intended for heating, they must have their own aeration and/or ventilation opening. The air inlets must meet the following requirements: Š they must be protected with grids, metal mesh, etc., but without reducing the net useful section; Š...
  • Page 16: Pellets And Feeding

    Pellets and feeding Pellets are made by applying high pressure to sawdust, or wood waste products (not containing paint) from sawmills, carpentry and other activities related to processing and working with wood. Given that it does not use any glue to hold it together this type of fuel is completely environmentally friendly. In fact the compactness of the pellets over time is guaranteed by a natural substance found in the wood itself: wood coal.
  • Page 17: Touch Screen Display

    TOUCH SCREEN DISPLAY The boiler is equipped with a modern touch-screen display that allows the adjustment of the individual device functions in an easy and intuitive way to the user. All adjustments and settings depicted in the screens can be performed directly via the integrated touch-screen display. Tapping the buttons (icons) on the display surface the different actions are activated.
  • Page 18: Control Panel And Icons

    CONTROL PANEL AND ICONS icon meaning • Indicates the presence of an alarm. The machine will turn off. • This indicates the system pressure detected by the machine. • It indicates the pump operation: Off = pump OFF; ON = pump on Flashing ling = the safety device is active (H2O temperature >...
  • Page 19: Key Functions

    kEY fUNCTIONS funcTion funcTion press and hold for more than 2 seconds to Allows increases/select (+) or decrease (-) turn on or turn off the boiler. a mode (seT) press and hold for more than 2 seconds to Allows you to scroll through the menus exit the menu.
  • Page 20: Commissioning Settings

    COMMISSIONINg SETTINgS Once the power cable at the back of the generator has been connected, move the switch, located on the back, to position (I). The switch at the back of the generator powers the generator board. The generator stays off and the panel shows an initial screen with the word off. MAINS fREqUENCY 50/ 60Hz in the event the generator is installed in a country with 60hz frequency, the generator will display "incorrecT Line freQuency".
  • Page 21: Operation And Logics

    OPERATION AND LOgICS IgNITION Once you have checked the "basic instructions" listed above, press the for more than two seconds to turn on the generator. 15 minutes are available for the ignition phase. After ignition and having reached the control temperature, the generator stops the ignition phase and passes to sTArTing.
  • Page 22: Stby - Additional Room Thermostat

    STBY - ADDITIONAL ROOM THERMOSTAT PLEASE NOTE : Installation must be performed by an authorised technician is it possible to thermostat a room adjacent to the room where it was placed the generator just connecting a room thermostat according to the procedure described in the next step (it is advisable to position the optional mechanical thermostat at a height of 1.50 m from the floor) .
  • Page 23: Set Power

    SET POWER The following menu allows to set the power. Minimum power 1, maximum power 5. TEMPERATURE SET The following menu allows the boiler temperature to be set. Possible setting are: 65 - 80°C. USER REgULATION The user reguLATion allows you to: �...
  • Page 24: Enable Chrono

    • ENABLE CHRONO it allows to enable/disable the chrono and the various time slots of the boiler. EASY SETUP The volumetric weight of the pellet is the ratio between the weight and the volume of the pellet. This ratio can change while maintaining the quality of the pellet.
  • Page 25: Chrono

    • CHRONO The chrono allows to program 4 time spans within a day to use every day of the week. The switch-on and switch-off time can be set in every time slot, along with the days of use of the programmed time slot and the desired water temperature (65 - 80°C).
  • Page 26: Reset

    � BUzzER when set to "off" the acoustic signal is disabled. � BRIgHTNESS It allows you to adjust the backlight of the display. The possible settings range from off - 10 to 30. Activating OFF, the back light of the display will go off after a preset delay.
  • Page 27: Cleaning And Maintenance

    Cleaning and MaintenanCe always follow the instruCtions in MaxiMuM safety Conditions! Š Make sue the power cable is unplugged since the generator could be programmed to start. Š That the generator is cold in its entirety. Š The ashes are completely cold. Š...
  • Page 28 daily - sCrapers: hp15evo - hp22evo: The heat exchangers must only be cleaned when the generator is cold! Cleaning the heat exchangers allows to ensure constant heat output over time. This type of maintenance must be performed at least once a day. To do this, just use the relevant scrapers positioned in the upper part of the generator, making the upward movements and vice versa several times.
  • Page 29: Routine Maintenance Performed By Qualified Technicians

    routine MaintenanCe perforMed by Qualified teChniCians routine maintenance must be performed at least once a year. Since the generator uses pellets as its solid fuel, it requires an annual routine maintenance operation which must be performed by a qualified technician, using original spare parts only. Failure to comply with the above can compromise the safety of the appliance and void the the guarantee conditions.
  • Page 30 routine MaintenanCe THE PICTURES ARE PURELY INDICATIVE. HP15EVO HP30EVO HP22EVO Fumes motor (disassembly and cleaning and flue duct and "T"), new silicone in the dedicated points Inspection of gaskets, ash drawer and door (replace and apply silicone where envisaged) Combustion chamber, door "air" slots and heat exchanger (full cleaning) including ignition-plug pipe cleaning Tank (complete emptying and cleaning) Air intake pipe check and cleaning of the flow sensor where necessary ENGLISH...
  • Page 31: Display

    DISPLAY DISPLAY REASON Generator off START Start phase in progress PELLET LOADING Continuous loading of pellets during ignition in progress IGNITION Ignition phase in progress BURNING Start-up phase in progress WORK Normal operation phase in progress MODULATION The generator is operating at minimum BURN POT Burning pot cleaning in progress CLEANING...
  • Page 32 fUMES PROBE Fumes probe fault. Contact customer service Check the pellet loading (see “Easy Setup”); if the problem persists, contact a HOT EXHAUST High fume temperature qualified technician The door is not closed properly. Check the hermetic closure of the door. The ash drawer is not closed properly.
  • Page 33: Guarantee Terms

    Extraflame S.p.A. cannot be held liable for injury or damage which may - either directly or indirectly - be caused to persons, animals and property ensuing from failure to observe all the instructions provided in the relevant instruction manual and the warnings regarding installation, use and maintenance of the product, that can also be downloaded on the website.
  • Page 34: Disposal

    AddITIONAL wARNINGs Š Only use the fuel recommended by the manufacturer. The product must not be used as an incinerator. Š Do not use the product as a ladder or supporting structure. Š Do not place laundry on the product to dry it. Any clothes-horse or similar objects must be kept at due distance from the product. Danger of fire or damage to the coating.
  • Page 35 ENGLISH...
  • Page 36 Extraflame S.p.A. Via Dell’Artigianato, 12 36030 - MONTECCHIO PRECALCINO (VI) - ITALY   +39.0445.865911 -  +39.0445.865912 -  info@extraflame.it - www.lanordica-extraflame.com MADE ITALY design & production TO FIND THE SERVICE CENTRE NEAREST TO YOU CONTACT YOUR DEALER OR CONSULT THE SITE WWW.LANORDICA-EXTRAFLAME.COM...