Section 6. Maintenance; General Maintenance; Pressure Gauge; Cleaning The Filter Cartridge - Jandy CS150 Installation And Operation Manual

Single element cartridge pool & spa cs filters
Table of Contents

Advertisement

Jandy
Pro Series, CS Single Element Cartridge Pool & Spa Filter
®
5.
Remove the top of the filter. Inspect the tank
o-ring for damage. Clean or replace the o-ring as
necessary.
6.
Remove the filter element from the tank bottom
and clean or replace as necessary.
7.
Place the new or cleaned filter element into the
tank bottom.
8.
Use a silicone based lubricant on the new or
cleaned o-ring and place the o-ring onto the tank
top.
9.
Place the tank top onto the tank bottom. Be sure
the tank halves are seated properly.
10.
Tighten the locking ring, see Section 3.4,
"Locking Ring/Tank Top Assembly Installation".
11.
Follow steps 5 thru 8 under Section 4.1, "New
Pool and Seasonal Start-Up".
WARNING
If the breather tube is not fully seated
or is damaged or clogged, trapped
air can cause product failure or also
cause the filter lid to be blown off
which can result in death, serious
personal injury or property damage.
Tank Top
Breather Tube
Tank Bottom
Figure 6.
Filter Element Removal
|
Installation & Operation Manual
Air
Release
Valve
Locking
Ring
Filter Element

Section 6. Maintenance

6.1

General Maintenance

1.
Wash outside of filter with water or TSP (tri-
sodium phosphate) with water. Rinse off with
a hose. Do not use solvents or detergents to
clean the filter, solvents will damage the plastic
components of the filter.
2.
Check pressure during operation at least once a
week.
3.
Remove any debris from the skimmer basket and
hair/lint pot on pump.
4.
Check pump and filter for any leaks. If any leaks
develop, turn off the pump and call a qualified
pool service technician.
5.
Product safety signs or labels should be
periodically inspected and cleaned by the product
user as necessary to maintain good legibility for
safe viewing.
6.
Product safety signs or labels should be replaced
by the product user when a person with normal
vision, including corrected vision, is no longer
able to read the safety signs or label message
panel text at a safe viewing distance from
the hazard. In cases where the product has an
extensive expected life or is exposed to extreme
conditions, the product user should contact either
the product manufacturer or other appropriate
source to determine means for obtaining
replacement signs or labels.
7.
Installation of new replacement safety signs or
labels should be in accordance with the sign or
label manufacturer's recommended procedure.
6.2

Pressure Gauge

CAUTION
Maintain your pressure gauge in good working order.
The pressure gauge is the primary indicator of how the
filter is operating.
1.
During operation of the filtration system, check
the pressure gauge/air release assembly for air or
water leaks at least once a week.
2.
Keep the pressure gauge in good working order.
If you suspect a problem with the gauge, Zodiac
Pool Systems LLC recommends you call a service
technician to do any work on the filter/pump system.
6.3

Cleaning the Filter Cartridge

off
1.
Turn
the filter pump and switch off the circuit
breaker to the pump motor.
2.
If the filter is installed below pool level, close any
filter isolation valves to prevent flooding.
Page 9
ENGLISH

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs100Pro seriesCs200Cs250

Table of Contents