8- Power on the XN120

1
Power on the XN120.
2
The VOIPU card(s) will be
automatically configured.
XN120 Voice Over IP Card Guide
! System Start Up – Retain Customer Configuration
This is the normal operation for powering the XN120 on.
Before you power on the system check that the NORMAL switch is set
to ON. This will ensure that the system memory retains your
configuration.
The NORMAL switch is located to the right of the MOH/Page
connector on the main unit, refer to the Getting Started Guide supplied
with the XN120 for further information.
Check the VOIPU card(s) has automatically configured by the LIVE
lamp flashing green on each card.
If the LIVE lamp is off the card is not initialised correctly.
Check the card is fully inserted into the slot (power off the system first).
Check the slot has not had a different type of card installed, see
Program 10-03-01 below.
Check there are sufficient trunk ports available on the system,
maximum of 51 trunks.
Power on the XN120