UG-322
OPERATING THE SOFTWARE
The main window of the
EVAL-AD5110SDZ
into the following sections: QUICK COMMANDS, MANUAL
DATA, RDAC, and MEMORY. The features of the main
window are as follows:
•
The QUICK COMMANDS section allows you to send
quick commands directly to the AD5110.
•
The RDAC section can be used to update the RDAC
registers by typing a value into a text box and clicking
WRITE. When WRITE is clicked or a quick command
is executed, a write-read operation is performed and the
software is divided
Rev. 0 | Page 6 of 12
Evaluation Board User Guide
values displayed in this section are updated with the actual
RDAC register values.
•
The MANUAL DATA can be used to send a customized
I
2
C data word by manually switching the scroll bars from 0
to 1 or from 1 to 0, as desired, and then clicking SEND
DATA. The scroll bars are updated upon each write
transfer.
•
The MEMORY section displays the data stored in the
memory block. The data can be updated manually by
clicking UPDATE.
•
Clicking EXIT closes the program but does not reset the part.