MLC Plus 50/100/200 Series • Setup Guide (Continued)
Control and power — LAN (Ethernet) and PoE
Activity LED: Blinks yellow
to indicate data is being
sent or received.
MLC
Side
Panel
Link LED: Lights green
to indicate a network
connection.
12345678
Twisted Pair
ATTENTION:
• Power over Ethernet (PoE) is intended for indoor use only. It is to be connected only to networks or circuits that are not
routed to the outside plant or building.
• L'alimentation via Ethernet (PoE) est destinée à une utilisation en intérieur uniquement. Elle doit être connectée
seulement à des réseaux ou des circuits qui ne sont pas routés au réseau ou au bâtiment extérieur.
Control, bidirectional — serial (COM)
Rear Panel
Tx Rx G
Tx Rx G
S
G
POWER
COM 1
COM 2
IR
12V
0.4A MAX
Heat Shrink
Over Shield Wires
To 3-pole
COM port
Control — IR output
Rear
Panel
Tx Rx G
S
G
V
C
G
COM 2
IR
VOL
or
G
Ground
S
IR Output
Unidirectional IR
To Projector, Panel Display, or the Wired
Ground
IR Output
3/16" (5 mm) max.
6
Connect to an Ethernet network. This port must be con gured.
Default protocol:
• MLC IP address: 192.168.254.250
• Gateway IP address: 0.0.0.0
• Subnet mask: 255.255.255.0
• DNS address: 127.0.0.1
• DHCP: off
Pins:
• Link speed and duplex level:
autodetected
• Data rates: 10/100/1000Base-T
Use this port to upload con guration
les and rmware.
PC
Insert
Wires
TCP/IP
Ethernet
Network
Select protocol via software. COM port default protocol:
• 9600 baud
3-pole COM
• 8 data bits • 1 stop bit
(RS-232)
• no parity
NOTE: These COM ports support software ow control only.
G
Ground
Rx
Receive
Tx
Transmit
IR Output Port
Output options:
• IR (30 kHz to 300 kHz,
with or without carrier signals)
Two Single IR Emitters
(-)
(+)
(-)
(-)
(+)
(+)
IR Remote of a Source Device
LAN/PoE (Ethernet and Power Over Ethernet)
NOTE:
MAC address information
(00-05-A6-##-##-##) is
located on the front panel
(behind the faceplate).
Power over Ethernet (PoE):
• If PoE is available, the MLC Plus uses PoE.
• If PoE is dropped (disconnects), the
controller switches seamlessly to the
external 12 VDC power supply, if it is
installed.
IMPORTANT NOTES:
• The factory con gured passwords for this device have been
set to the device serial number. Passwords are case
sensitive. Performing a "Reset to Factory Defaults" reset
Extron
(see
(see
Reset Modes: a Brief Summary
Reset Modes: a Brief Summary
Devices
passwords to
(Switchers,
Scalers)
• DHCP is off by default
Serial (COM) Ports
• no ow control
RS-232-
Receive (Rx)
Controllable
Transmit (Tx)
Device
Strip wires
3/16" (5 mm) max.
Ground (−)
IR Signal (+)
To the
IR Receiver of
Ground (−)
a Projector,
Display, or
Source Device
IR Signal (+)
00-05-A6-XX-XX-XX
MAC: 00-05-A6-XX-XX-XX
S/N: ####### E######
MAC: 00-05-A6-XX-XX-XX
S/N: ####### E######
Default login credentials:
• Username: admin or user
• Initial password:
unit serial number
• Password after a "Reset to
Factory Defaults": extron
on page 11
on page
extron
.
NOTE:
If you use cable
that has a drain wire,
tie the drain wire to
ground at both ends.
One Single IR Emitter
(−)
(+)
(−)
(+)
Two Single IR Emitters
MAC
Address
) sets the