7.3 Type tests and environmental conditions

Phenomena
Test
ESD
EN 61000-4-2
RF field AM
EN 61000-4-3
modulated
Fast transient
EN 61000-4-4
Surge
EN 61000-4-5
RF conducted
EN 61000-4-6
Radiated emission
EN 55022
Conducted
EN 55022
emission
Power frequency
EN 61000-4-8
magnetic field
Dry heat
EN 60068-2-2
Cold
EN 60068-2-1
Damp heat
EN 60068-2-78
Vibration
EN 60068-2-64
ed. 2
Shock
EN 60068-2-27
ed. 2
Table 33: Type tests and environmental conditions
* The temperatures given are for the basic version of the router. These can vary for other versions.
SmartFlex SR303
Description
Test levels
Enclosure contact
6 kV (crit. A)
Enclosure air
8 kV (crit. A)
Enclosure
20 V/m (crit. A)
(80 – 2700 MHz)
3 V/m (crit. A)
(2700 – 6000 MHz)
Signal ports
2 kV (crit. A)
Power ports
2 kV (crit. A)
Ethernet ports
2 kV (crit. A)
Ethernet ports
2 kV (crit. B), shielded cab.
Power ports
0,5 kV (crit. B)
I/O ports
1 kV, L to L (crit. A)
2 kV, L to GND (crit. A)
All ports
10 V/m (crit. A)
(0,15 – 80 MHz)
Enclosure
Class B
DC power ports
Class B
Ethernet ports
Class B
Enclosure
160 A/m (crit. A)
+75 C *, 40 % rel. humidity
-40 C *
95 % rel. humidity (+40 C)
Vibration spectrum
Category 1 (3 axis, 8 hours per
A.3 (rolling stock)
axis)
half-sine, 50 g peak, 11 ms
47