Primary Input - ESAB Aristo Mig U5000i Instruction Manual

Hide thumbs Also See for Aristo Mig U5000i:
Table of Contents

Advertisement

US
8.3

Primary input

ELECTRIC SCHOCK CAN KILL! Precautionary measures should be taken to provide maximum
protection against electrical shock.
Be sure that all power is OFF by opening the line (wall) disconnect switch when primary
electrical connections are made to the power source.
Be sure to check your input leads with a voltmeter to make sure all power is OFF.
Recommended fuse sizes and minimum cable areas
Mig U5000i
Mains voltage
Mains cable area, CU/AWG (mm
Phase current, I RMS
Fuse Time Delay
NB!
Sizes per National Electric Code for 90˚C rated cooper conductors @30˚C ambient. Not more than
three conductors in raceway or cable. Local codes should be followed if they specify larger sizes other
than those listed above.
bu16d1aa
Check that the unit is connected to the correct mains power supply
voltage, and that it is protected by the correct fuse sizes. A
protective earth connection must be made, in accordance with
regulations.
Rating plate with supply connection data
460 V 3μ 60 Hz
2)
- - 15 - -
460 V
10(6)
28 A
50 A

Advertisement

Table of Contents
loading

Table of Contents