Omron Sysmac NY Series Hardware User Manual page 126

Hide thumbs Also See for Sysmac NY Series:
Table of Contents

Advertisement

5 Installation
Power Connector Wiring Procedure
Use the following procedure to wire the power connector.
1
Remove the sheath from the power supply wires.
Precautions for Safe Use
Observe the following precautions to prevent broken wires.
• When you remove the sheath, be careful not to damage the conductor.
• Connect the conductor without twisting the wires.
• Do not weld the conductors. Doing so may cause the wires to break with vibration.
2
Insert a screwdriver in the small opening above the cable opening
and then push the wire all the way to the back of the cable opening
Pin
1
2
3
Remove the screwdriver.
Do not apply stress to the cable after you have connected the wires.
5-38
1
2
24 VDC
0 VDC
7 mm
1
2
Description
NY-series IPC RTOS Controller Hardware User's Manual (W581)
1
to unlock the cable entry
2
.

Advertisement