Conformity To Ul Standards; Built-In Holding Brake - Panasonic MHMD042P1C Technical Reference

Ac servo motor & driver
Table of Contents

Advertisement

7. Conformity to EC Directives and UL Standards
Noise Filter for Signal Lines *
Install noise filters for signal lines to all cables (power cable, motor cable, encoder cable
and interface cable)
* In case of D-frame, install 3 noise
filters at power line.
DV0P1460
Option part No.
ZCAT3035-1330
Manufacturer's part No.
TDK Corp.
Manufacturer
<Caution> Fix the signal line noise filter in place to eliminate excessive stress to the cables.
Ground-Fault Breaker
Install a type B ground fault breaker (RCD) at primary side of the power supply.
Grounding
(1) Connect the protective earth terminal (
terminal (PE) of the control box without fail to prevent electrical shocks.
(2) Do not make a joint connection to the protective earth terminals (
provided for protective earth.
<Note>
For driver and applicable peripheral equipments, refer to P.B14 "Driver and List of Ap-
plicable Peripheral Equipments" .

Conformity to UL Standards

Observe the following conditions of (1) and (2) to make the system conform to UL508C
(File No. E164620).
(1) Use the driver in an environment of Pollution Degree 2 or 1 prescribed in IEC60664-
1. (e.g. Install in the control box with IP54 enclosure.)
(2) Install a circuit breaker or fuse which are UL recognized (Listed
the power supply and the noise filter without fail.
For the rated current of the circuit breaker or fuse, refer to P.32, "Driver and List of
Applicable Peripheral Equipments" of Preparation.
Use a copper cable with temperature rating of 60˚C or higher.
Tightening torque of more than the max. values (M4:1.2N
the terminal block.
(3) Over-load protection level
Over-load protective function will be activated when the effective current exceeds 115%
or more than the rated current based on the time characteristics. Confirm that the effec-
tive current of the driver does not exceed the rated current. Set up the peak permissible
current with Pr5E (Setup of 1st torque limit) and Pr5F (Setup 2nd torque limit).
39±1
34±1
Mass: 62.8g
) of the driver and the protective earth
). 2 terminals are
marked) between
m, M5: 2.0N
m) may break
– B44 –

8. Built-in Holding Brake

In the applications where the motor drives the vertical axis, this brake would be used to
hold and prevent the work (moving load) from falling by gravity while the power to the
servo is shut off.
Use this built-in brake for "Holding" purpose only, that is to hold the stalling status.
Never use this for "Brake" purpose to stop the load in motion.
Output Timing of BRK-OFF Signal
• For the brake release timing at power-on, or braking timing at Servo-OFF/Servo-Alarm
while the motor is in motion, refer to the technical reference. (DV0P4210)
• With the parameter, Pr6B (Setup of mechanical brake action while the motor is in
motion), you can set up a time between when the motor enters to a free-run from
energized status and when BRK-OFF signal turns off (brake will be engaged), when
the Servo-OFF or alarm occurs while the motor is in motion.
<Notes>
1. The lining sound of the brake (chattering and etc.) might be generated while running
the motor with built-in brake, however this does not affect any functionality.
2. Magnetic flux might be generated through the motor shaft while the brake coil is ener-
gized (brake is open). Pay an extra attention when magnetic sensors are used nearby
the motor.
Specifications of Built-in Holding Brake
Static
Rotor
Motor
Motor
friction
inertia
torque
x 10
–4
series
output
N
m
kg
m
50W, 100W
0.29 or more
0.002
MSMD
200W, 400W
1.27 or more
0.018
MAMA
750W
2.45 or more
0.075
100W
0.29 or more
0.03
MQMA
200W, 400W
1.27 or more
0.09
1.0kW
4.9 or more
0.25
1.5kW, 2.0kW
7.8 or more
0.33
MSMA
3.0kW
11.8 or more
4.0kW, 5.0kW
16.1 or more
1.35
(Continues to next page)
Exciting
Engaging
Releasing
Permissible
Releasing
current
time
time
work (J) per
DC A
voltage
ms
ms*
one braking
2
(at cool-off)
35 or less
0.25
39.2
10 or less
DC2V
50 or less
0.30
137
or more
70 or less
20 or less
0.35
196
50 or less
0.29
DC1V
137
15 or less
60 or less
0.41
or more
196
0.74
50 or less
15 (100)
392
or less
0.81
DC2V
80 or less
or more
50 (130)
110 or less
0.90
1470
or less
– B45 –
Permissible
total work
x 10
J
3
4.9
44.1
147
44.1
147
196
490
2156