Temperature Errors - Alcatel-Lucent OmniSwitch 6860N Hardware User's Manual

Table of Contents

Advertisement

Chassis and Power Supplies

Temperature Errors

The switch monitors the ambient air temperature at all times via an onboard sensor. If an over-temperature
condition occurs, there are two different levels of error severity:
Warning threshold has been exceeded
Danger threshold has been exceeded
Warning Threshold
If the temperature exceeds the switch's warning threshold, the switch sends out a trap. Traps are printed to
the console in the form of text error messages.
When the warning threshold has been exceeded, switch operations remain active. However, it is
recommended that immediate steps be taken to address the over-temperature condition.
Addressing warning threshold temperature conditions may include:
Checking for a chassis airflow obstruction
Checking the ambient room temperature
Temperature Danger Threshold
If the chassis ambient air temperature rises above the danger threshold, the switch will power off until the
temperature conditions have been addressed and the switch is manually booted. The danger threshold is
factory-set and cannot be configured by the user.
Addressing danger threshold temperature conditions may include:
Checking for a chassis airflow obstruction
Checking the ambient room temperature
OmniSwitch 6860 Hardware Users Guide
October 2022
Monitoring Chassis Temperature
page 3-63

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Omniswitch 6860eOmniswitch 6860

Table of Contents