Intrinsically Safe Fm; Non-Incendive Fm; Intrinsically Safe Csa; Non-Incendive Csa - ABB TTF300 Series Commissioning Instructions

Field-mounted temperature transmitter
Hide thumbs Also See for TTF300 Series:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 39
LCD-Anzeiger Typ B
6.4.4

Intrinsically Safe FM

I.S. Class I Div 1 und Div 2, Group: A, B, C, D oder
I.S. Class I Zone 0 AEx ia IIC T*
*Temp. Ident: T6 T
56 °C, T4 T
amb
U i / V
= 9V, I i / I
< 65,2 mA, P i = 101 mW
max
max
C i = 0,4 µF; L i = 0
Control Drawing: SAP_214 748
6.4.5

Non-Incendive FM

N.I. Class I Div 2, Group: A, B, C, D oder
Ex nL IIC T*, Class I Zone 2
*Temp. Ident: T6 T
60 °C, T4 T
amb
U i / V
= 9V, I i / I
< 65,2 mA, P i = 101 mW
max
max
C i = 0,4 µF; L i = 0
Control Drawing: SAP_214 751
Wechsel ein-auf zweispaltig
34 - DE
85 °C
amb
85 °C
amb
6.4.6

Intrinsically Safe CSA

I.S. Class I Div 1 und Div 2; Group: A, B, C, D oder
I.S Zone 0 Ex ia IIC T*
*Temp. Ident T6 T
amb
U i / V
= 9V, I i / I
max
max
C i < 0,4 µ F, L i = 0
Control Drawing: SAP_214 749
6.4.7

Non-Incendive CSA

N.I. Class I Div 2, Group: A, B, C, D oder
Ex nL IIC T*, Class I Zone 2
*Temp. Ident T6, T
amb
U i / V
= 9V, I i / I
max
max
C i < 0,4 µF, L i = 0
Control Drawing: SAP_214 750
TTF300
56 C, T4 T
85 °C
amb
< 65,2 mA; P i = 101 mW
60 °C, T4 T
85 °C
amb
< 65,2 mA, P i = 101 mW
CI/TTF300-X1

Advertisement

Table of Contents
loading

Table of Contents