Machine description – quick overview
Machine control – Operating elements
4.3
Machine control – Operating elements
Item Symbol
1
2
3
4
VRD
5
AMP%
6
7
8
9
AMP
10
sec
11
16
Description
0
Display, 3-digit
Collective interference signal light
For error messages, > see 7 chapter
Excess temperature signal light
In case of excess temperature, temperature monitors de-activate the power unit, and
the excess temperature control lamp comes on. Once the machine has cooled down,
welding can continue without any further measures.
Voltage reduction device (VRD) signal light > see 5.7 chapter
Hotstart current signal light
Welding parameter setting rotary transducer
Setting of welding current and other welding parameter and their values
Select welding parameters button
This button is used to select the welding parameters depending on the welding process
and operating mode used.
Pulse welding (average value pulses) signal light > see 5.2.6 chapter
On: ------- Function switched on
Not on: -- Function switched off
Flashing: Parameter selection and frequency setting
Main current signal light
Imin to Imax (1 A increments)
Hotstart time signal light
Welding procedure/power-saving mode push-button
---- MMA welding
-------- TIG welding
Press for 2 s to put the machine into power-saving mode. To reactivate, activate one of
the operating elements > see 5.5 chapter.