Save the carton and all packing materials. In the event that a fixture must be returned to the factory, it is important that the fixture be returned in the original factory box and packing. Your shipment includes: ● Showtec Cameleon Flood 15 Q4 ● 1x Schuko to 3-pins (IP-65 ) Power cable 1,5m ●...
Page 4
● If your Showtec device fails to work properly, discontinue the use immediately. Pack the unit securely (preferably in the original packing material), and return it to your Showtec dealer for service.
Cameleon Flood 15 Q4 ● The user is responsible for correct positioning and operating of the Cameleon Flood 15 Q4. The manufacturer will not accept liability for damages caused by the misuse or incorrect installation of this device. ● This device falls under protection class I. Therefore it is essential to connect the yellow/green conductor to earth.
Cameleon Flood 15 Q4 The Cameleon Flood 15 Q4 can be placed on a flat stage floor or mounted to any kind of truss with a clamp. Improper installation can cause serious injuries and/or damage of property! Connection with the mains Connect the device to the mains with the power-plug.
Cameleon Flood 15 Q4 Return Procedure Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. Call Highlite 0031-455667723 or mail aftersales@highlite.nl and request an RMA prior to shipping the fixture.
Cameleon Flood 15 Q4 Description of the device Features The Cameleon Flood 15 Q4 is a wall washer with great output and effects. It is an extension on our Cameleon series. It's an indoor and outdoor solution for illumination of numerous objects. ●...
Cameleon Flood 15 Q4 Overview Fig. 01 01) 15x 5W 4-in-1 RGBW ProLight Opto Hornet Series 02) IR-remote sensor 03) Mounting bracket Backside Fig. 02 04) Special mini 3-pin DMX cable IN IP-65 05) Special mini 3-pin DMX cable OUT IP-65 06) Special mini 3-pin power cable IN IP-65 07) OLED Display + control buttons 08) Special mini 3-pin power cable OUT IP-65...
Cameleon Flood 15 Q4 Installation Remove all packing materials from the Cameleon Flood 15 Q4. Check if all foam and plastic padding is removed. Connect all cables. Do not supply power before the whole system is set up and connected properly. Always disconnect from electric mains power supply before cleaning or servicing.
Cameleon Flood 15 Q4 Multiple Cameleon Floods (Master/Slave control) 01) Fasten the effect light onto firm trussing. Leave at least 0,5 meter on all sides for air circulation. 02) Always use a safety cable (ordercode 70140 / 70141). 03) Use a 3-p XLR cable to connect the Cameleon Floods and other devices. The pins: 1.
Cameleon Flood 15 Q4 Multiple Cameleon Floods (DMX Control) 01) Fasten the effect light onto firm trussing. Leave at least 0,5 meter on all sides for air circulation. 02) Always use a safety cable (ordercode 70140 / 70141). 03) Use a 3-pin XLR cable to connect the Cameleon Floods and other devices. 04) Link the units as shown in fig.
Cameleon Flood 15 Q4 Fixture Linking You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to run synchronized shows of two or more fixtures set to a master/slave operating mode. The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support.
Cameleon Flood 15 Q4 Control Panel A) OLED Display MODE button C) SET button D) UP button DOWN button Fig. 05 Control Mode The fixtures are individually addressed on a data-link and connected to the controller. The fixtures respond to the DMX signal from the controller. (When you select the DMX address and save it, the controller will display the saved DMX address, next time.) DMX Addressing The control panel on the front side of the base allows you to assign DMX fixture addresses, which is the first...
Cameleon Flood 15 Q4 Main Menu Options 01) Upon start-up, the display will show one screen: 02) Press the SET or MODE button to open the main menu. The display will show: 03) Press the UP/DOWN buttons to toggle between the menus. 04) Press the SET button to open the desired menu.
Cameleon Flood 15 Q4 3. DMX Address/ DMX Configuration With this menu you can set the device’s DMX starting address and choose a DMX channel mode. 01) While in the main menu, press the UP/DOWN buttons to choose DMX. 02) Press the SET button to open the menu. 03) Press the UP/DOWN buttons to choose between Address or Channels.
Cameleon Flood 15 Q4 6. Settings With this menu you can set the device’s settings. 01) While in the main menu, press the UP/DOWN buttons to choose Settings. 02) Press the SET button to open the menu. 03) Press the UP/DOWN buttons to toggle between the following menus: Curves Select, Dimmer Speed, Dmx Fail, Dmx Sync, Lock, Factory.
Cameleon Flood 15 Q4 6.3. Dmx Fail With this menu, you can adjust the behaviour of the device in case of a DMX signal error . 01) While in Settings menu, press the UP/DOWN buttons to choose Dmx Fail. 02) Press the SET button to open the menu. 03) Press the UP/DOWN buttons to choose the desired option.
Cameleon Flood 15 Q4 Optional remote control Button Function Description On / Off Switch the device ON or OFF Auto Activates the Auto program Program Activates the Built-in programs No function Speed Activates the Program speed mode Strobe Activates the Strobe frequency mode Dimming Activates the Manual Color mode Plus...
Cameleon Flood 15 Q4 Button Function Description Color 9 Activates color 9 (R000, G255, B000, W150) Color 6 Activates color 6 (R255, G255, B000, W000) Color 15 Activates color 15 (R000, G255, B255, W075) Color 11 Activates color 11 (R000, G255, B000, W000) Color 12 Activates color 12 (R000, G255, B050, W000) Color 13...
Cameleon Flood 15 Q4 DMX Channels 4 DMX Channels Channel 1 – Red Dimmer intensity 0-255 Gradual adjustment Red from 0-100% Channel 2 – Green Dimmer intensity 0-255 Gradual adjustment Green from 0-100% Channel 3 – Blue Dimmer intensity 0-255 Gradual adjustment Blue from 0-100% Channel 4 –...
Page 23
Cameleon Flood 15 Q4 Channel 4 – Color presets (CH1 must be set between 1-255 No function 8-13 Color 1 (R255, G000, B000, W000) 14-20 Color 2 (R255, G000, B000, W100) 21-27 Color 3 (R255, G000, B000, W200) 28-34 Color 4 (R255, G050, B000, W000) 35-41 Color 5 (R255, G150, B000, W000) 42-48...
01) Power supply. Check that the unit is plugged into an appropriate power supply. 02) The LEDs. Return the Cameleon Flood to your Showtec dealer. 03) The internal fuse. Return the Cameleon Flood to your Showtec dealer. 04) If all of the above appears to be O.K., plug the unit in again.
Internal fuse blown • Return the Cameleon Flood to your Showtec dealer Fixtures reset The controller is not connected • Connect controller correctly, but all 3-pin XLR Out of the controller •...