SHOWTEC Cameleon Flood 15 Q6 Tour V1 User Manual
SHOWTEC Cameleon Flood 15 Q6 Tour V1 User Manual

SHOWTEC Cameleon Flood 15 Q6 Tour V1 User Manual

Hide thumbs Also See for Cameleon Flood 15 Q6 Tour V1:
Table of Contents

Advertisement

Quick Links

USER MANUAL
ENGLISH
Cameleon Flood 15 Q6 Tour
V1
Product code: 42684
Highlite International B.V. – Vestastraat 2 – 6468 EX – Kerkrade – the Netherlands

Advertisement

Table of Contents
loading

Summary of Contents for SHOWTEC Cameleon Flood 15 Q6 Tour V1

  • Page 1 USER MANUAL ENGLISH Cameleon Flood 15 Q6 Tour Product code: 42684 Highlite International B.V. – Vestastraat 2 – 6468 EX – Kerkrade – the Netherlands...
  • Page 2 Cameleon Flood 15 Q6 Tour Preface Thank you for purchasing this Showtec product. The purpose of this user manual is to provide instructions for the correct and safe use of this product. Keep the user manual for future reference as it is an integral part of the product. The user manual shall be stored at an easily accessible location.
  • Page 3: Table Of Contents

    Cameleon Flood 15 Q6 Tour Table of contents Introduction ................................4 Before Using the Product ..........................4 Intended Use ............................... 4 Product Lifespan ..............................4 LEDs Lifespan ............................... 4 Text Conventions ..............................4 Symbols and Signal Words ..........................5 Symbols on the Information Label ........................5 Safety ..................................
  • Page 4 Cameleon Flood 15 Q6 Tour DMX Fail ..............................27 DMX Sync .............................27 Lock ...............................28 Factory ..............................28 Information ..............................28 DMX Channels ..............................29 6 Channels, 8 Channels, 12 Channels ....................29 6.8. RDM Information ...............................31 6.8.1. RDM Details ..............................31 6.8.2. Supported RDM PIDs (Parameter IDs) ....................31 6.8.3.
  • Page 5: Introduction

    After unpacking, check the contents of the box. If any parts are missing or damaged, contact your Highlite International dealer. Your shipment includes: ● Showtec Cameleon Flood 15 Q6 Tour ● Schuko to Power Pro True cable (1,5 m) ●...
  • Page 6: Symbols And Signal Words

    Cameleon Flood 15 Q6 Tour Symbols and Signal Words Safety notes and warnings are indicated throughout the user manual by safety signs. Always follow the instructions provided in this user manual. Indicates an imminently hazardous situation which, if not avoided, will result in DANGER death or serious injury.
  • Page 7: Safety

    Cameleon Flood 15 Q6 Tour Safety Important Read and follow the instructions in this user manual before installing, operating or servicing this product. The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual. Warnings and Safety Instructions DANGER Danger for children...
  • Page 8 Cameleon Flood 15 Q6 Tour WARNING Risk of epileptic shock Strobe lighting can trigger seizures in photosensitive epilepsy. Sensitive persons should avoid looking at strobe lights. CAUTION Possible eye damage caused by high light intensity Possibly hazardous optical radiation emitted from this device. Do not look at the operating light source.
  • Page 9: Requirements For The User

    Cameleon Flood 15 Q6 Tour This device is designed to be used as a professional outdoor wall washer. Any incorrect use may lead to hazardous situations and result in injuries and material damage. ● This device is not suitable for households and for general lighting. ●...
  • Page 10: Description Of The Device

    Cameleon Flood 15 Q6 Tour Description of the Device The Showtec Cameleon Flood 15 Q6 Tour is an IP65-rated outdoor wall washer. It is equipped with 15 x 10 W 6-in-1 RGBWA-UV LEDs. Front View 01) Infrared sensor 02) 15 x 10 W RGBWA-UV LEDs 03) Mounting bracket Fig.
  • Page 11: Product Specifications

    Maximum housing temperature t 70 °C Minimum distance: Minimum distance from flammable surfaces: Minimum distance to lighted object: 0,5 m Optional Accessories You can additionally purchase the following accessories: Product code: 44002 (Showtec UR-5 Universal IR Remote) Product code: 42684...
  • Page 12: Dimensions

    Cameleon Flood 15 Q6 Tour Dimensions Fig. 04 Product code: 42684...
  • Page 13: Installation

    Cameleon Flood 15 Q6 Tour Installation Safety Instructions for Installation WARNING Incorrect installation can cause serious injuries and damage of property. If trussing systems are used, installation must be carried out only by instructed or skilled persons. Follow all applicable European, national and local safety regulations concerning rigging and trussing. Personal Protective Equipment During installation and rigging wear personal protective equipment in compliance with the national and site-specific regulations.
  • Page 14: Rigging

    Cameleon Flood 15 Q6 Tour Rigging The device can be positioned on a flat surface or mounted to a truss or other rigging structure. Make sure that all loads are within the pre-determined limits of the supporting structure. CAUTION Restrict the access under the work area during rigging and/or derigging. To mount the device, follow the steps below: 01) Use a clamp to attach the device to the supporting structure, as shown in Fig.
  • Page 15: Connecting To Power Supply

    Cameleon Flood 15 Q6 Tour Connecting to Power Supply DANGER Electric shock caused by short-circuit The device accepts AC mains power at 100–240 V and 50/60 Hz. Do not supply power at any other voltage or frequency to the device. This device falls under IEC protection class I.
  • Page 16: Setup

    Cameleon Flood 15 Q6 Tour Setup Warnings and Precautions DANGER Electric shock caused by short-circuit This device is IP65 rated. ● Do not expose the device to conditions that exceed the rated IP class conditions. ● Keep the connectors sealed with the rubber caps when the connectors are not in use. ●...
  • Page 17: Dmx Cables

    Cameleon Flood 15 Q6 Tour DMX Cables Shielded twisted-pair cables with 3-pin XLR connectors must be used for reliable DMX connection. You can purchase DMX cables directly from your Highlite International dealer or make your own cables. If you use XLR audio cables for DMX data transmission, this may lead to signal degradation and unreliable operation of the DMX network.
  • Page 18: Dmx Linking

    Cameleon Flood 15 Q6 Tour DMX Linking To connect multiple devices on one DMX data link, follow the steps below: 01) Use a 3-pin DMX cable to connect the DMX OUT connector of the lighting controller to the DMX IN connector of the first device.
  • Page 19: Operation

    Cameleon Flood 15 Q6 Tour Operation Safety Instructions for Operation Attention This device must be used only for the purposes it is designed for. This device is intended for professional use as an outdoor wall washer. It is not suitable for households and for general lighting.
  • Page 20: Control Panel

    Cameleon Flood 15 Q6 Tour Control Panel A) OLED display DOWN button C) UP button D) SET button MODE button Fig. 10 ● Use the MODE button to exit the current submenu and to return to the Main Menu. ● Use the UP/DOWN buttons to navigate through the menus or to increase/decrease numeric values.
  • Page 21: Menu Overview

    Cameleon Flood 15 Q6 Tour Menu Overview Product code: 42684...
  • Page 22 Cameleon Flood 15 Q6 Tour Product code: 42684...
  • Page 23: Main Menu Options

    Cameleon Flood 15 Q6 Tour Main Menu Options Upon start-up, the display will show the current software version and the temperature. The main menu has the following options: ● Touch the UP/DOWN buttons to navigate through the main menu. ● Touch the SET button to open the submenus.
  • Page 24: Address

    Cameleon Flood 15 Q6 Tour Address In this menu you can set the desired DMX starting address. 01) Touch the UP/DOWN buttons to set the desired DMX address. The adjustment range is 001–512. 02) Touch the SET button to confirm your choice. Channels In this menu you can set the desired DMX channel mode.
  • Page 25: Auto

    Cameleon Flood 15 Q6 Tour Auto In this menu you can set Auto mode. 01) While in the main menu, touch the UP/DOWN buttons to choose AUTO. 02) Touch the SET button to enter the menu. The display will show: 03) Touch the UP/DOWN buttons to choose YES (to start the auto show) or NO (to return to the previous screen.
  • Page 26: Programs 02-16

    Cameleon Flood 15 Q6 Tour Program 01 01) If you choose program 01, the display will show: Touch the UP/DOWN buttons to choose one of the 2 options: ● COLOR ● STROBE Touch the SET button to enter the desired menu. If you chose COLOR, touch the UP/DOWN buttons to choose one of the 33 color macros.
  • Page 27: Settings

    Cameleon Flood 15 Q6 Tour Settings In this menu you can adjust the device’s settings. 01) While in the main menu, touch the UP/DOWN buttons to choose SETTINGS. 02) Touch the SET button to enter the menu. The display will show: 03) Touch the UP/DOWN buttons to choose one of the 6 submenus: ●...
  • Page 28: Dimmer Speed

    Cameleon Flood 15 Q6 Tour Dimmer Speed In this menu you can set the dimmer speed. 01) Touch the UP/DOWN buttons to select FAST or SMOOTH. 02) Touch the SET button to confirm your choice. DMX Fail In this menu you can set the device’s behavior in case of a DMX failure. 01) Touch the UP/DOWN buttons to select one of the 4 options: ●...
  • Page 29: Lock

    Cameleon Flood 15 Q6 Tour Lock In this menu you can set the safety lock, restricting access to the main menu. 01) Touch the UP/DOWN buttons to select one of the 2 options: ● ON: when no button is pressed within 30 seconds, the device’s main menu will be locked. In order to unlock it, press and hold down the MODE and SET buttons for 3 seconds.
  • Page 30: Dmx Channels

    Cameleon Flood 15 Q6 Tour DMX Channels 6 Channels, 8 Channels, 12 Channels 6 CH 8 CH 12 CH Function Value Setting Master Dimmer 000–255 From low to high intensity (0–100 %) 000–010 No function Linear Strobe 011–255 From` low to high frequency (0–15 Hz) 000–010 No function Pulse Strobe...
  • Page 31 Cameleon Flood 15 Q6 Tour 6 CH 8 CH 12 CH Function Value Setting 080–095 Color switch 5 096–111 Color switch 6 112–127 Color switch 7 128–143 Color switch 8 144–159 Color fade 1 160–175 Color fade 2 176–191 Color fade 3 192–207 Color fade 4 208–223...
  • Page 32: Rdm Information

    This device supports RDM. Refer to 6.8.2. Supported RDM PIDs (Parameter IDs) for more information. 6.8.1. RDM Details ● Responder: 29B4:0C1xxxxx ● Manufacturer's ID: Showtec (Highlite International B.V.) ● Manufacturer Label: Showtec ● Model Description: Cameleon Flood 15Q6 Tour ●...
  • Page 33: Remote Control

    Cameleon Flood 15 Q6 Tour Remote Control The device can be controlled with an IR remote control (44002). DANGER Do not ingest battery, chemical burn hazard The remote control contains a coin cell battery. If the coin cell battery is swallowed, it can cause severe internal burns in just 2 hours and can lead to death.
  • Page 34 Cameleon Flood 15 Q6 Tour To operate the device with the IR remote control, point the remote control to the infrared sensor (01). Note: The remote control will work only if the device is already operating in Auto, Built-in Programs or Manual mode.
  • Page 35: Auto

    Cameleon Flood 15 Q6 Tour Button Function Description Activates Red LEDs Green Activates Green LEDs Blue Activates Blue LEDs Amber Activates Amber LEDs White Activates White LEDs Activates UV LEDs Color 22 (purple) Activates color 22 (R 160; G 000; B 255; W 000) Color 23 (purple/pink) Activates color 23 (R 255;...
  • Page 36: Program Speed

    Cameleon Flood 15 Q6 Tour Program Speed Press the button to set the program speed. Press the buttons to increase/decrease the program speed. The adjustment range is 1– 100, from slow to fast. Note: If you select program 1 and start adjusting the program speed, the device will automatically switch to program 2.
  • Page 37: Troubleshooting

    Cameleon Flood 15 Q6 Tour Troubleshooting This troubleshooting guide contains solutions to problems which can be carried out by an ordinary person. The device does not contain user-serviceable parts. Unauthorized modifications to the device will render the warranty void. Such modifications may result in injuries and material damage.
  • Page 38: Maintenance

    Cameleon Flood 15 Q6 Tour Maintenance Safety Instructions for Maintenance DANGER Electric shock caused by dangerous voltage inside Disconnect power supply before servicing or cleaning. Preventive Maintenance Attention Before each use, examine the device visually for any defects. Make sure that: ●...
  • Page 39: Draining Condensation Water

    Cameleon Flood 15 Q6 Tour Draining Condensation Water The Cameleon Flood 15 Q6 Tour is IP65 rated. The device can resist water jets. If the device is exposed to extreme humid conditions during servicing, condensation may collect inside the device. This can happen also during transportation, if the device is exposed to extreme temperature variations.
  • Page 40: Deinstallation, Transportation And Storage

    Cameleon Flood 15 Q6 Tour Deinstallation, Transportation and Storage Instructions for Deinstallation WARNING Incorrect deinstallation can cause serious injuries and damage of property. ● Let the device cool down before dismounting. ● Disconnect power supply before deinstallation. ● Always observe the national and site-specific regulations during deinstallation and derigging of the device.
  • Page 41 Cameleon Flood 15 Q6 Tour Product code: 42684...
  • Page 42 Cameleon Flood 15 Q6 Tour Product code: 42684...
  • Page 43 Cameleon Flood 15 Q6 Tour Product code: 42684...
  • Page 44 ©2023 Showtec...

This manual is also suitable for:

42684

Table of Contents