Figure 2B: Basic Wiring Diagram For Manager Controller, Dual Drive Operation - Curtis 1232E Manual

Hide thumbs Also See for 1232E:
Table of Contents

Advertisement

Return to TOC
The manager controller is wired to all the components except those related to the Right motor and
the steering pot.
EMERG. REV.
INTERLOCK
FORWARD
REVERSE
LEFT MOTOR
TEMP
SENSOR
Note: KTY sensor shown.
The banded end must be
connected to I/O ground.
THROTTLE
POT
BRAK
POT
Figure 2b
Basic wiring diagram for manager controller, Dual Drive operation.
2 — WIRING
Curtis 1232E/34E/36E/38E/39E & 1232SE/34SE/36SE/38SE Manual, os37.0 – May 2021
J1-24
SWITCH 1 /
COIL RETURN
ANALOG 1
J1-9
SWITCH 3
J1-10
SWITCH 4
J1-11
SWITCH 5
J1-12
SWITCH 6
J1-22
SWITCH 7
PROP. DRIVER
J1-33
SWITCH 8
DIG. DRIVER 6
J1-14
SWITCH 16
DIG. DRIVER 7
J1-8
SWITCH 2 /
ANALOG 2
J1-7
I/O GROUND
POSITION FEEDBACK A
POSITION FEEDBACK B
I/O GROUND
J1-30
ANALOG OUT
(0–10V)
CAN TERM H
CAN TERM L
J1-15
THROTTLE
POT HIGH
J1-16
THROTTLE
POT WIPER
J1-27
POT2 HIGH
J1-17
POT2 WIPER
J1-18
I/O GROUND
POT LOW
MANAGER CONTROLLER
1232E/34E/36E/38E/39E
1232SE/34SE/36SE/38SE
J1-1
KSI
J1-13
KSI
MAIN
J1-6
DRIVER 1
BRAKE
J1-5
DRIVER 2
J1-4
DRIVER 3
J1-3
DRIVER 4
J1-2
J1-10
J1-20
B+
U
V
MOTOR
W
J1-26
+5V
J1-31
POSITION
J1-32
FEEDBACK
J1-7
DEVICE
B-
J1-21
Connect jumper for 120Ω
J1-34
CAN bus termination
J1-23
CAN H
J1-35
CAN L
J1-25
+12V
J1-28
TX
J1-29
RX
J1-7
8
CURTIS
6
MODEL 840
5
DISPLAY
to KSI (J1-1) on
ancillary controller
KEYSWITCH
to B+ on
ancillary controller
MAIN
LEFT
EMERGENCY
STOP
AC
BATTERY
(24–96V)
to B- on
ancillary controller
to J1-23 on ancillary controller
to J1-35 on ancillary controller
4
3
SERIAL PORT
1
(4-pin Molex)
2
pg. 3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1234e1236e1238e1239e1232se1234se ... Show all

Table of Contents