9. Reassemble the Unit
5.1.4 SCREEN ELEMENT
The screen attached to the rim with adhesion
may have noticeable damage. Replace if:
•
Tearing appears
•
Holes are found through screen
•
Screen is detached from rim
Replace by disassembling the screen from the
unit and contact HK Technologies for shipment
for rescreening.
1. Disconnect Power
24
WE MAKE SIFTING OPERATIONS
•
Disconnect power
•
Remove the band clamps
•
Remove the ultrasonic rim
•
Using the quick disconnect on the
pigtail wire to the ultrasonic power
supply disconnect the line before
rotating and remove the ultrasonic
booster from rim with spanner wrench
•
Remove any gaskets from the ultrasonic
rim
•
Ready for shipping? See Sect. 5.2 for
details.
2. Remove Band Clamps
2: Rotate
3: Pull Apart
1: Rotate
BETTER.