5.1.2 GASKET SEAL
Wear to the rubber gasket placed around the unit's outer rims maybe noticed. Do not hesitate to
replace them if:
Tearing or wear patterns occur
•
•
Stretched and oversized to rim
•
Surface cracks appear
•
Does not retain seal during operation
Product leakage
•
To replace gasket:
•
Make sure power is disconnected
•
Remove the band clamps
Remove the ultrasonic rim from the assembly
•
•
Pry away the gasket away from the sealed surface around the rim, use a screwdriver if
necessary see Fig. 3.2 for gasket location.
Peel the gasket away from rim
•
•
Apply new gasket once all pieces of the previous gasket have been removed
•
Reassemble the unit
1. Disconnect Power
WE MAKE SIFTING OPERATIONS
2. Remove Band Clamps
2: Rotate
3: Pull Apart
1: Rotate
BETTER.