Zip HydroTap G5 Quick Start Installation Manual

Zip HydroTap G5 Quick Start Installation Manual

Command center, boiling, chilled & sparkling
Hide thumbs Also See for HydroTap G5:

Advertisement

Quick Links

uick start installation guide
Q
Zip
HydroTap G5
Command Center
Boiling, Chilled & Sparkling models
AFFIX PRODUCT LABEL HERE
English
French
Visit our website to
download the manuals
Quick Start Installation Guide
1
807119US v1.04 11.22 G5 BCS Quick Start Guide

Advertisement

Table of Contents
loading

Summary of Contents for Zip HydroTap G5

  • Page 1 HydroTap G5 Command Center Boiling, Chilled & Sparkling models AFFIX PRODUCT LABEL HERE English French Visit our website to download the manuals Quick Start Installation Guide 807119US v1.04 11.22 G5 BCS Quick Start Guide...
  • Page 2: Table Of Contents

    Table of contents SECTION 1: Using these instructions Before you start SECTION 1: Using these instructions ..............3 SECTION 2: IMPORTANT SAFETY INSTRUCTIONS ..........4 This document is a Quick Start Installation Guide. SECTION 3: WARNINGS & REGULATORY INFORMATION ........7 For further details on installing and operating your HydroTap download &...
  • Page 3: Section 2: Important Safety Instructions

    SECTION 2: IMPORTANT SAFETY INSTRUCTIONS SECTION 2: IMPORTANT SAFETY INSTRUCTIONS Compliance • Use only in an upright position. All Plumbing and Electrical connections must comply with local, • The cylinder must be used with the supplied pressure regulator. state and federal codes. •...
  • Page 4: Section 3: Warnings & Regulatory Information

    1Ω. Use the power cable supplied. It is the responsibility of the installer to ensure the power point is earthed. The HydroTap G5 Home series is intended to be used in household and similar applications such as: • All installation and service work must be completed by trained and suitably qualified tradespeople.
  • Page 5: Section 4: Technical Data

    If the power 9.9A 13.3 (339) x 18.2 (462) x 13.1 (333) 75 (34) supply cord is damaged it must be replaced by a Zip service provider or Home (1200W) a qualified electrician.
  • Page 6: Section 5: Parts Supplied, Consumables And Accessories

    Drip tray kit Optional Optional Note: Mains water isolation valve is not supplied with the kit. Contact Zip for the full range of consumables and accessories. Quick Start Installation Guide Quick Start Installation Guide 807119US v1.04 11.22 G5 BCS Quick Start Guide...
  • Page 7 (supplied) Vent tray If cupboard temperature exceeds 95°F, (35°C) additional ventilation is required. Contact your Zip service provider for options (including additional vents and fan kit). Vent tray dimensions WxDxH inch (mm): 19.7 (500) x 20.3-21.8 (515-555) x 1.6 (40)
  • Page 8: Section 7: Fit The Carbonation Valve

    SECTION 8: Connect the water supply SECTION 7: Fit the carbonation valve Valves and fittings must be sealed with PTFE tape if compression Classic, Wave, Celsius Arc and Cube Avoid seals are not included. Classic Plus, Elite Plus Note: Mixer tap installations also use a ‘tee piece’ as part of the water supply plumbing connections, see the Tap installation instructions supplied with the Mixer Tap to connect the water supply if using the mixer tap option.
  • Page 9: Section 9: Set The Bypass & Install The Limescale Filter

    SECTION 9: Set the bypass & install the limescale filter SECTION 10: Install the CO2 cylinder and regulator Available as optional accessory. Be aware of the risks of hazards which could cause harm when handling For filter head and scale filter installation use the guide supplied compressed CO2.
  • Page 10 SECTION 10: Install the CO2 cylinder and regulator SECTION 10: Install the CO2 cylinder and regulator Adjust the G5 regulator Do not proceed if the seals are damaged. Cylinder pressure • Check the regulator control is turned Take care not to cross thread the regulator, a cross threaded all the way OFF (anti-clockwise).
  • Page 11: Section 11: Connect The Command Center

    SECTION 11: Connect the Command Center SECTION 11: Connect the Command Center Generic installation instructions John Guest pipe and fittings Take care to use correctly, see below : For HydroTap, mixer tap and any optional accessories, use instructions supplied with individual kit components. Insert Remove Mains power cable...
  • Page 12 B res comm SECTION 11: Connect the Command Center SECTION 11: Connect the Command Center BCS60 models BCS20 & BCS Home models Limescale filter ER BOILING BYPASS VENT BYPASS (optional) YPASS MAINS MIXER MIXER BOILING BYPASS VENT BYPASS Limescale filter (optional) AMBIENT BCS comm OUTLET...
  • Page 13: Section 12: Commissioning

    Drip tray Sink Select the language, date / time & drain away options • Initial commissioning screen touch COMMISSIONING 12:12 PM Language option. HydroTap G5 Language 024-H5v0.1.16 BCS100 0000000000000 H50063000US • Touch the appropriate button to select LANGUAGE 10:50 the language and units of choice.
  • Page 14 SECTION 12: Commissioning SECTION 12: Commissioning Filter flush Tank flush (does not apply to chilled sparkling models) • Follow the steps on-screen to flush the • Follow the instructions to flush the tanks. TANK FLUSH 12:12 PM filter. Dispense water from the tap if instructed. Fresh water will be flushed through the tank/s multiple times as shown by the cycle counter/s.
  • Page 15 SECTION 12: Commissioning SECTION 12: Commissioning purge Backflow Prevention PURGE WATER WITH CO2 12:12 PM All HydroTap models that have sparkling/carbonated water functionality • CO2 life settings should be adjusted for the INFO include the following integral Backflow Prevention. This process removes water from the sparkling size of the CO2 bottle connected.
  • Page 16: Section 13: Performance Data Sheets

    Performance Data Sheet Some authorities require additional Backflow Prevention to be installed to Zip HydroTap G5 BCS Home with ARC XX, CUBE XX, Celsius AIO XX, Classic XX, Wave XX, comply with the Local, State or Federal plumbing code requirements. Both the Classic Plus XX, Elite Plus XX, ARC Plus XX, and CUBE Plus XX faucets.
  • Page 17: Warranty

    Performance Data Sheet Limited Warranty- Zip Products Zip HydroTap G5 BCS60, HydroTap G5 BCS20 with ARC XX, CUBE XX, Celsius AIO XX, What Does This Warranty Cover? Classic XX, Wave XX, Classic Plus XX, Elite Plus XX, ARC Plus XX, and CUBE Plus XX faucets.
  • Page 18 Zip Customer. • Freight or shipping charges for sending a Zip Product to a Zip Repair Center. How to Obtain Warranty Service for The Zip Product? • Products installed in cabinetry and other types of built-in applications If during the relevant warranty period the Zip Customer finds the Zip Product that are not accessible to the service technician.
  • Page 19 Images in this booklet have been modified and may not be true representations of the finished goods. The terms “Zip” and “HydroTap” are registered trade marks of Zip Heaters (Aust) Pty Ltd. BCS60, BCS20, and BCS Home systems certified by IAPMO R&T against NSF/ANSI Standard 42, NSF/ANSI Standard 53, NSF/ANSI Standard 372, CSA B483.1, ASSE 1023, and ASSE 1087.

This manual is also suitable for:

Bcs60Bcs20Bcs home

Table of Contents