AFFIX PRODUCT LABEL HERE
English
French
Visit our website to
download the manuals
Quick Start Installation Guide
1
807118US v1.02 11.22 G5 BC Quick Start Guide

Advertisement

Table of Contents
loading

Summary of Contents for Zip HydroTap G5

  • Page 1 Start Installation Guide HydroTap G5 Command Center Boiling/Chilled models AFFIX PRODUCT LABEL HERE English French Visit our website to download the manuals Quick Start Installation Guide 807118US v1.02 11.22 G5 BC Quick Start Guide...
  • Page 2: Table Of Contents

    Table of contents SECTION 1: Using these instructions ..............2 SECTION 2: IMPORTANT SAFETY INSTRUCTIONS ..........3 SECTION 3: WARNINGS & REGULATORY INFORMATION ........5 SECTION 4: Technical data .................7 SECTION 5: Parts supplied ................. 8 SECTION 6: Set up the ventilation ................9 SECTION 7: Connect the water supply .............
  • Page 3: Section 2: Important Safety Instructions

    SECTION 2: IMPORTANT SAFETY INSTRUCTIONS Compliance All Plumbing and Electrical connections must comply with local, state and federal codes. All Plumbing and Electrical connections must be made in accordance with local regulations. Ensure the electrical power supply at the installation site is suitable for your HydroTap.
  • Page 4 Command Center electrically. This safeguard does not offer the same protection to the connecting pipework and fittings. Application The HydroTap G5 Home series is intended to be used in household and similar applications such as: • Staff kitchen areas in shops, offices and other working environments;...
  • Page 5: Section 3: Warnings & Regulatory Information

    • Never locate the system near, or clean with water jets. • Do not expose the Zip HydroTap to the elements of nature. • Use of tools can be hazardous. Assess the risks before you start.
  • Page 6 SECTION 3: WARNINGS & REGULATORY INFORMATION supply cord is damaged it must be replaced by a Zip service provider or a qualified electrician. • Do not locate multiple portable socket-outlets or portable power supplies at the rear of the appliance.
  • Page 7: Section 4: Technical Data

    SECTION 4: Technical data Technical data Dimensions Weight 220-240V 110-120V Model 50/60Hz 50/60Hz W x D x H inch, (mm) lb (kg) 15.5 (395) x 18.3 (464) x 13.1 (333) With Duct 9.5A BC40 17.7 (450) x 18.3 (464) x 13.1 (333) 66 (30) (1970W) With Duct and Vent Tray:...
  • Page 8: Section 5: Parts Supplied

    Drip tray Drip tray kit Optional Optional Note: Mains water isolation valve is not supplied with the kit. Contact Zip for the full range of consumables and accessories. Quick Start Installation Guide 807118US v1.02 11.22 G5 BC Quick Start Guide...
  • Page 9: Section 6: Set Up The Ventilation

    SECTION 6: Set up the ventilation Use of tools can be hazardous. Assess the risks before you start. Use instructions supplied with individual kit parts. A clearance envelope around all Command Centers must be provided to allow ventilation for the safe and effective use of the HydroTap system.
  • Page 10 SECTION 6: Set up the ventilation BC40 models • Cold air is drawn in through the inlet vent and gap provided by the door buffers. • Inlet vent is mounted over cupboard side, door or floor cut-out (see below). • Warm air is exhausted through vent tray. •...
  • Page 11 Air inlet Inlet vent All models If cupboard temperature exceeds 95°F, (35°C) additional ventilation is required. Contact your Zip service provider for options (including additional vents and fan kit). Quick Start Installation Guide 807118US v1.02 11.22 G5 BC Quick Start Guide...
  • Page 12: Section 7: Connect The Water Supply

    SECTION 7: Connect the water supply Valves and fittings must be sealed with PTFE tape if compression seals are not included. Note Mixer installations also use a ‘Tee piece’ as part of the water supply plumbing connections, see the faucet installation instructions supplied with the Mixer faucet to connect the water supply if using the mixer option.
  • Page 13: Section 8: Set The Bypass & Install The Limescale Filter

    SECTION 8: Set the bypass & install the limescale filter Available as optional accessory. For filter head and scale filter installation use the guide supplied with the filter head and filter respectively. Water Water Bypass in Bypass out see pages 16,17 see pages 16,17 Insert Remove...
  • Page 14: Section 9: Connect The Command Center

    SECTION 9: Connect the Command Center Generic installation instructions For HydroTap, mixer faucet and any optional accessories, use instructions supplied with individual kit components. Mains power cable Braided hose HydroTap Command Connections key Do not connect to the mains Center socket until commissioning Warning: HydroTap models are available for either 110-120VAC 50/60Hz or 220-240VAC 50/60Hz installations.
  • Page 15 SECTION 9: Connect the Command Center John Guest pipe and fittings Take care to use correctly, see below : Insert Remove 2. Pull pipe 1. Cut pipe clean & square 1. Press collet 2. Push pipe to down end stop Installation diagrams are for illustrative purposes only.
  • Page 16 SECTION 9: Connect the Command Center CHILLED MAINS OUTLET BC40 models Limescale filter (optional) hich way round arkling Mains Fit foam insulation Water (supplied) to the BLUE pipe Do not MAINS PARKLING BLUE CLEAR OUTLET connect without HydroTap Venturi kit BC comm CHILLED MAINS...
  • Page 17 SECTION 9: Connect the Command Center MAINS BC Home models Limescale filter BC comm (optional) CHILLED MAINS MIXER MIXER BOILING BYPASS VENT BYPASS Mains BYPASS OUTLET Fit foam insulation Water (supplied) to the BLUE pipe Do not MAINS BLUE CLEAR connect without HydroTap...
  • Page 18: Section 10: Commissioning

    Select the language, date / time & drain away options • Initial commissioning screen touch COMMISSIONING 12:12 PM Language option. HydroTap G5 Language 024-H5v0.1.16 BCS100 0000000000000 H50063000US • Touch the appropriate button to select...
  • Page 19 SECTION 10: Commissioning • Touch the arrow to continue when ready COMMISSIONING 12:12 PM to start using the HydroTap. Your HydroTap is designed to be used frequently, do not commission until ready for use. Please follow commissioning guidelines in the manual. •...
  • Page 20 SECTION 10: Commissioning Filter flush • Follow the steps on-screen to flush the filter. • Open filter door & uncoil flush line. • Direct flush line into bucket. • Place a cloth or towel under the filter cartridge to catch any water that may spill.
  • Page 21 SECTION 10: Commissioning Tank flush (does not apply to chilled sparkling models) • Follow the instructions to flush the tanks. TANK FLUSH 12:12 PM Dispense water from the tap if instructed. Fresh water will be flushed through the tank/s multiple times as shown by the cycle counter/s. •...
  • Page 22 SECTION 10: Commissioning Safety sensor calibration (Classic boiling models only) Optional, in cases where light recalibration is required. Light intensity varies from site to site, therefore it is recommended that a re-calibration be performed at the time of the installation. All direct sunlight must be shaded from the HydroTap, during the calibration.
  • Page 23: Section 11: Performance Data Sheets

    SECTION 11: Performance data sheets Performance Data Sheet Zip HydroTap G5 BC40 with ARC XX, CUBE XX, Classic XX, Wave XX, Classic Plus XX, Elite Plus XX, ARC Plus XX, and CUBE Plus XX faucets. Manufacturer: Zip Heaters (Aust) Pty Ltd...
  • Page 24 SECTION 11: Performance data sheets Performance Data Sheet Zip HydroTap G5 BC Home with ARC XX, CUBE XX, Classic XX, Wave XX, Classic Plus XX, Elite Plus XX, ARC Plus XX, and CUBE Plus XX faucets. Manufacturer: Zip Heaters (Aust) Pty Ltd...
  • Page 25: Warranty

    Two (2) Year Limited Warranty - Any warranty claims for Zip Products must be received by Zip within 15 months from the date of purchase or within 12 months from date of installation. This warranty guarantees that if any part...
  • Page 26 • Zip Products covered by third party “Extended Warranties”, which are sold separately by dealers, distributors or other third parties. • Freight or shipping charges for sending a Zip Product to a Zip Repair Center. • Products installed in cabinetry and other types of built-in applications that are not accessible to the service technician.
  • Page 27 Limited Warranty, the Zip service agent will either repair (if possible) or make arrangements for the repair of the Zip Product at no cost to you. This will include parts and labor. Zip reserves the right to charge for exceptional shipping or transportation costs (e.g., ferries, plane trips or excess mileage) as...
  • Page 28 Call US Toll Free 1-833-233-2358 for assistance, service, spare parts or enquiries. As Zip policy is one of continuous product improvement, changes to specifications may be made without prior notice. Images in this booklet have been modified and may not be true representations of the finished goods.

This manual is also suitable for:

Bc40Bc home

Table of Contents