Lenze 9200 Series Operating Instructions Manual page 71

Table of Contents

Advertisement

Code Name
Parameter
C061 Utilization I x t
C067 Fault diagnosis
C068
Operating state
(L)
C069
Controller state
(L)
C070 V
(gain of
pn
speed
controller)
C071* T
n
(Integral action
time of speed
controller)
C072* k
d
(differential
amplification of
speed
controller)
C079* V
p
(V
-controller)
z
C080* T
n
(V
-controller)
z
C081* Rated motor
power
C087 Rated motor
speed
C088 Rated motor
current
C089 Rated motor
frequency
C091 cos ϕ Motor
C093* Controller
identification
C094* Pass word
C098 Language
C099* Software
version
C105 Quick stop
deceleration
time T
QSP

xxxx
Setting range: 0.0...+100.0%
Step:
0.1%
The indicated value is determined by
the current-time integral I x t of the
controller current. When reaching
100% the I x t monitoring sets
overload trip
xxx
see under "Service"
see under "Service"
see under "Service"
30
Setting range: 0...500
Step:
1
10
Setting range: 2.5...100 ms
Step:
0.5 ms
9999
Deactivate integral component
0
Setting range: 0...5
Step:
0.1
1000
Setting range: 0...9000
Step:
1
1.0 s
Setting range: 0.01...150
xxx.x
Setting range: 0.1...650 kW
Step:
0.1 kW
xxxx
Setting range: 300...6000 rpm
Step:
1 rpm
xxx
Setting range: 0.1A...max. controller
current
Step:
0.01 A
xxx.x
Setting range: 10.0...300.0 Hz
Step:
0.1 Hz
x.xx
Setting range: 0.50...0.99
Step:
0.01
xx
0
enter any password (0...999)
no password defined
-0-
German
-1-
English
-2-
French
Note:
The setting will not be overwritten
when loading the factory setting!
92_5.x Number to identify the software
version
0.01
Setting range: 0.00...990 s
Step:
0.01 s from 0.00...1 s
0.1 s from 1...10 s
1 s from 10...100 s
10 s from 100...990 s
Accept-
see
ance
page
read only
74
read only
59
read only
59
ON-LINE
49
ON-LINE
49
ON-LINE
49
ON-LINE
53
ON-LINE
53
47
read only
SH+PRG
42
read only
ON-LINE
48
67