Code Name
Parameter
C025* Encoder
C026* Encoder
constant
C027* Encoder setting
C028* Encoder setting
2
C030* Encoder
simulation
C031* n
offset
C032* Ratio
numerator
C033* Ratio
denominator
C039 JOG speed
C040 RFR (controller
enable)

-0-
noe encoder selected for setting
-1-
bipolar set value X5, terminals 1, 2
-3-
Dig. Set master frequency X2
-5-
unipolar set value X5, terminals 7, 8
-13-
act. resolver value X3
-0-
no encoder constant
-1-
512 increments/revolution
-2-
1024 increments/revolution
-3-
2048 increments/revolution
-4-
4096 increments/revolution
-0-
no setting required
1.000
Setting range: -5...0...+5
LECOM:
-5000...0...+5000
Step:
0.001
Adjustable speed ratio between slave
and master drive n
using the Dig. Set input.
-0-
no setting required
1.000
Setting range: -5...0...+5
LECOM:
-5000...0...+5000
Step:
0.001
Second adjustable speed ratio for the
Dig. Set input. The controller is
enabled (changing the parameter
form C027 to C028) via code C 140.
-1-
256 increments/revolution
-2-
512 increments/revolution
-3-
1024 increments/revolution
-4-
2048 increments/revolution
0
Setting range: -1000...+1000
Step:
10 mV
Offset adjustment of the selected
analog speed set value input
0.1
Setting range: -3.2767...+3.2767
Step:
0.0001
Numerator of the gearbox factor for
the Dig. Set input. The total ratio can
be obtained from the follow. formula:
C027 C032
V =
C033
Due to an internal limitation, only
values from V= -5.000...+5.000 can
be realized.
0.1
Setting range: +0.0001...+3.2767
Step:
0.0001
Denominator of the gearbox factor for
the Dig.Set input (formula: see C032)
20
Setting range: -n
Step:
1 rpm
-0-
Controller inhibited
-1-
Controller enabled
Accept-
ance
SH+PRG
SH+PRG
ON-LINE
/n
when
set
master
ON-LINE
SH+PRG
ON-LINE
ON-LINE
C028 C032
or V =
C033
ON-LINE
...+n
ON-LINE
max
max
SH+PRG
see
page
46
46
46
46
46
46
65