Lenze 9200 Series Operating Instructions Manual page 67

Table of Contents

Advertisement

6.
Code table
The following table shows which settings can be performed with
which codes. Detailed explanation about the codes and the
functions which can be achieved, are described in special chapters.
For the acceptance of parameters see page 41.
How to read the code table:
Column
Short form Meaning
Code
C000
C017*
C043 (L)
Parameter -0-
Acceptance ON-LINE
SH + PRG
Code Name
Parameter
C000 Code set
C001 Operating
mode
C002 Load parameter
set
C003 Store
parameter set
C004 Switch-on
display

Code digit of the standard code set
Code digit of the extended code set
Code digit can only be reached via the LECOM interface; code
is not displayed
The factory setting is printed in bold.
Unit immediately accepts new parameter
Unit accepts new parameter after pressing SH+PRG
Unit accepts parameter only if the controller is inhibited when
pressing SH+PRG.
-0-
Standard code set read only
-1-
Standard code set
-2-
Extended code set
-9-
Service code set (service password
neccessary)
-11-
Code set for
automation module
-P-
Password request
xxx
Enter password
Control:
Parameter setting:
-0-
Terminals
-1-
Keypad
-2-
Terminals
-3-
LECOM1
-4-
Terminals
-5-
LECOM2
-6-
LECOM2
-7-
LECOM2
-0-
Factory setting
-1-
Parameter set 1
51
Code no. for parameter displayed
after first switch-on
Accept-
see
ance
page
SH+PRG
password
SH+PRG
Keypad
Keypad
LECOM1
LECOM1
LECOM2
LECOM2
Keypad
LECOM1
SH+PRG
SH+PRG
45
45
57
63