1. POWER SUPPLY DURING REPAIRS
In this unit, about 25 seconds after power is supplied (8.4V) to the
battery terminal using the service power cord (J-6082-223-A), the
power is shut off so that the unit cannot operate.
This following two methods are available to prevent this. Take note of
which to use during repairs.
Method 1.
Connect the servicing remote commander RM-95 (J-6082-053-B) to
the LANC jack, and set the remote commander switch to the "ADJ"
side.
Method 2.
Press the following battery switch using adhesive tape, etc.
2. EJECTING WITH THE CABINET (L) ASSEMBLY
REMOVED
•
Refer to "2. DISASSEMBLY", and supply power with the cabinet
(L) assembly removed (however leaved the flexible board
connecting the cabinet (L) assembly and CB-58 board connected).
•
Ejecting:
Operate the slider, open the CS assembly (Cassette lid), turn
OFF the CC down switch, and press the Eject button again.
•
Loading:
Close the CS assembly (Cassette lid).
(Turn ON the CC down switch)
Slider
CC down switch
Push the ( section of slider to open the CS assembly (Cassette lid).
SERVICE NOTE
Battery terminal '
CS assembly
(Cassette lid)
Slider
(CC down switch : OFF)
— 4 —
Battery switch
Connect to CB-58 board.
OFF : Eject
ON : Loading
Battery SIG terminal
Battery terminal '
Need help?
Do you have a question about the DCR-TRV7 and is the answer not in the manual?
Questions and answers