Main Control Error List - JUKI K-1E Instruction Manual

Hide thumbs Also See for K-1E:
Table of Contents

Advertisement

6.3 Main Control Error List

6.3 Main Control Error List
Code
Name
Pedal not in the middle
E-001
position
E-002
Pause
E-003
Head Tilt Error
Main shaft driver
E-007
abnormal
E-008
24V power supply error
E-010
Air valve (fan) problem
Presser Foot Position
E-012
Error
E-013
Encoder Disconnection
Motor Running
E-014
Abnormal
E-015
Beyond Sewing Area
Needle Bar Up Position
E-016
Error
The thread is
E-017
interrupted during the
sewing process
E-018
Cutter Position Error
Content
Pedal is stepped down when entering the
ready sewing status
RESET key is pressed while sewing
machine is running. The machine
pauses.
Head tilt detection switch is set as ON.
The error is detected in main shaft
driver.
24V over-current
After start, the system detects abnormal
signal about the voltage of the air valve
or fan.
Presser foot is not at proper position.
The system can't detect ADTC signal.
When the main shaft motor is running,
the range of the electrical angle is
abnormal at 0°
The sewing area is beyond the limit.
The needle bar is not at UP position.
The pin bar is not in the upper position.
The cutter is not at the right position.
100
– 45 –
Solution
Make sure the pedal is not stepped down when
entering the ready sewing status
Restart or return-to-origin after pressing
RESET key for thread-trimming.
The sewing machine cannot be operated with
the head tilted. Return the sewing machine
head to its proper position. Technicians can use
short circuit board to short circuit the 2P blue
plug on the head board.
Turn off the power and repower the machine
after a while.
Turn off the power supply and then turn it on
again after a while.
Shut down the machine to check if there is any
short circuit
Turn off the power and check connection of the
CZ025 at the head signal circuit board. If the
connection is ok, check the optocoupler.
Turn off the power, and confirm whether plug
X5 is connected properly.
Shut down the machine to check the motor
encoder.
Press RESET switch to confirm the pattern and
its X/Y scale rate.
Triggering condition: pattern computation
error.
The main shaft stop position error may be
caused by main shaft drive, or may be caused
by human error. Turn the hand wheel to return
the needle bar to its UP position.
The spindle parking position is wrong, which
may be the cause of the spindle drive, or it may
be caused by human rotation. Turn the
handwheel to return the pin holder to the upper
position.
Turn off the power and check the connection of
the CZ024 at the head signal circuit board. If
the connection is ok, check the optocoupler.

Advertisement

Table of Contents
loading

Table of Contents