(1) X Size Input
Press
to display C001 X size.
Press
key to display the intended value.
X/Y size can be inputted by % or by actual size (set by
parameter U063) and the default setting is % input.
Note: if the set value is beyond the sewing range
allowed by the presser foot, the needle may collide with
the presser foot and thus cause needle breakage which
is very dangerous.
(2) Y Size Input
Press
to display C002 Y size.
Press
key to display the intended value.
X/Y size can be inputted by % or by actual size (set by
parameter U063) and the default setting is % input.
Note: if the set value is beyond the sewing range
allowed by the presser foot, the needle may collide with
the presser foot and thus cause needle breakage which
is very dangerous.
(3) Sewing Speed Input
Press
key to display C004 sewing speed.
Press
key to display the intended value.
The inputted value is limited by the max. Sewing speed
set by parameter U001.
(4) Line length force Setting
Press
key to display C003 thread tension.
Press
key to display the intended value. (input
range: 0~200)
Press
to confirm and return to the input interface.