Installation - Samoa 366010 Service Manual

1/2" pvc electronic meter
Table of Contents

Advertisement

Available languages

Available languages

EN
EN
INTRODUCTION
WARNING: this unit is intended for professional use. Read all the instructions in this manual prior to use.
• This meter is an oval gear model.
• Only use the unit for the purposes for which it is intended.
• This unit has not been approved for use in commercial
transactions.
• Do not alter or modify the unit.
• Do not exceed the maximum unit working pressure.
See page 7, technical specifications.
• Use the unit with fluids and solutions which are
compatible with the moist parts of the unit. See the
relevant section of the technical specifications.

INSTALLATION

The meter can be connected to a control gun or installed
directly in the distribution line pipe.
It is recommendable to install a cut-off valve before the
meter to facilitate its maintenance or repair.
The meter has a 1/2" BSP connection at the inlet and outlet.
It also includes an inlet flange and a flange at the outlet
BATTERIES
1
3
4
2
836 855 R. 03/23
SAMOA Industrial, S.A. · Pol. Ind. Porceyo, I-14 · Camino del Fontán, 831 · 33392 - Gijón - Spain · Tel.: +34 985 381 488 · www.samoaindustrial.com
• Observe the manufacturer's safety warnings for the
fluids used.
• The meter has been manufactured with low tolerances
in order to ensure high precision over a wide range of
flows and viscosity.
• Check measurement units counter before first use.
• In order to save energy the meter switches off
automatically after 30 seconds of inactivity. All the
data are stored for recovery once the meter has been
restarted.
which enables connection for the range of guns and original
Samoa accessories.
The meter requires two 1.5 V batteries and size LR 03 as
the power supply source. They are housed in a support
which, in conjunction with the lid design, prevents the
batteries from being removed accidentally in the event of
impacts or vibrations.
ATTENTION: The meter is supplied without the batteries
mounted. Follow the procedure below to install them.
1. Loosen the screws (1) and remove the battery housing
cover (2).
2. Install the provided batteries (3) checking that the polarity
2
matches the polarity symbols (4) marked in the housing.
3. Put in place the cover (2) and tighten the screws (1).
WARNING: to guarantee the battery cover
sealing, ensure that the battery is properly
positioned and the screws tightened.
When replacing the batteries the monitor briefly displays the
meter software version.