IntroductIon
WARNING: This unit is intended for professional use.
!
Read all the instructions in this manual prior to use.
• This unit is intended to be part of a fluid monitoring
system and allow its control. The unit comprises of an
oval gear meter.
• Only use the unit for the purposes for which it is
intended.
• This unit has not been approved for use in commercial
transactions.
• Do not alter or modify the unit.
• Do not exceed the maximum unit working pressure.
Consult technical specifications section for further details.

InStALLAtIon And coMMISSIonInG

COnneCTiOn TO hyDRauliC sysTem
This equipment is designed to be installed directly in the
distribution pipe line. The meter has a 1/2" BsP connection
at both inlet and outlet. it also includes an inlet flange and
an outlet flange with seating for an O-ring seal.
avoid installing the unit between rigid connections to
prevent efforts transmission of the pipeline.
it is recommended to install a pressure relief system on the
line to prevent damage from thermal expansion.
To prevent damage from dirt or solid particles carried by
the fluid is recommended the installation of a 200-mesh
strainer at the unit inlet.
it is advised to install the solenoid valve associated to the
u-meter at the unit inlet. Do not install the solenoid valve
at the unit outlet to avoid the unit being pressurized when
the valve is closed.
in figure 1 a typical installation is shown, which may vary
according to particular cases.

eleCTRiCal wiRing

!
WARNING: Disconnect the power source before servicing or repairing electrical equipment.
Solenoid valve installation (models without a factory
installed valve).
Connect both wires of the solenoid valve power supply
cable to the 2 pole male plug Pn 951978 (1). Then,
assemble the plastic housing Pn 951979 (2).
2
838 841 R. 12/18
SAMOA Industrial, S.A. · Pol. Ind. Porceyo, I-14 · Camino del Fontán, 831 · 33392 - Gijón - Spain · Tel.: +34 985 381 488 · www.samoaindustrial.com
• Only use the unit with fluids and solutions which are
compatible with the wetted parts of the unit. see the
relevant section of the technical specifications.
• Observe the manufacturer's safety warnings for the
fluids used.
• This meter has been manufactured with tight tolerances
in order to ensure high precision over a wide range of
flows and viscosity.
• Verify the correct settings of the monitoring system
prior to the first use.
• Operation with flow rates close to range ends may
cause a lack of accuracy of the measure. a calibration
procedure may be required in these cases.
1
2
flOw
direction
Fig. 1
Fig. 2