Samoa 366010 Service Manual page 4

1/2" pvc electronic meter
Table of Contents

Advertisement

Available languages

Available languages

EN
EN
OPERATING MODE
On/Off
• The meter is probably switched off when you wish
to use it.
• Press the ON/RESET button to switch it on (fig. 1). The
meter performs a check on the display by showing all the
segments briefly (fig. 2) and then on the display shows a
similar status to that shown (fig. 3).
• The display shows the partial meter.
Fig. 1
Fig. 2
• Although switched off, the meter automatically goes to an
On status when detecting fluid flow and starts to record
the quantity released by showing the partial meter.
• In order to save energy the meter switches off
automatically after 30 seconds of inactivity. The
registered data are stored.
OPERATING MODE
Trip function
The meter is fitted with a "Trip" meter which shows the
accumulated fluid volume released since the last "reset".
This function enables recording the register of the
fluid volume released from a barrel or tank. Set the
"Trip" meter to zero when starting a new barrel or
tank and then perform the individual transactions
with the partial meter. The partial meter can be reset
since this will not affect the "Trip" meter. Thus in the
"Trip" meter the volume released will be kept for all
transactions since the last reset and the remaining
volume in the barrel or tank can be ascertained.
When the meter is in normal status (partial meter) (fig.
7), the "Trip" meter can be shown by pressing the
SELECT button (fig. 8).
4
836 855 R. 03/23
SAMOA Industrial, S.A. · Pol. Ind. Porceyo, I-14 · Camino del Fontán, 831 · 33392 - Gijón - Spain · Tel.: +34 985 381 488 · www.samoaindustrial.com
Fluid release
• To release fluid, switch on the meter by pressing
the ON/RESET button or simply start to release and
the meter will automatically switch on by starting to
register the fluid.
• If, after successive measurements, (fig. 4) you wish to
set (fig. 6) the partial meter to zero, hold down the
ON/RESET button for a while (fig. 5).
Fig. 4
Fig. 3
• Each unit of volume released increases both the partial
meter and the total meter.
• When the meter switches off, or the batteries are
removed, the data of the last measurement taken are
stored.
The "Trip" meter (fig. 9) can be set to zero. To do so,
keep the ON/RESET button for a while when in "Trip"
mode.
The units shown in the "Trip" meter will be the same
as for those selected for the partial meter.
To return to normal mode (partial meter), press the
SELECT button twice in a row.
Fig. 5
Fig. 7
Fig. 8
Fig. 6
Fig. 9