Field Service Ver. 1.0 Aug. 2007
5.3.34
Pressure/retraction solenoid /2nd image transfer (SD4)
1. Remove the power supply cooling fan motor.
See P.60
[1]
[2]
2. Remove the tab [1] and the guide [2].
4139F2C581DA
3. Disconnect the connector [1].
4. Remove the mylar [2].
5. Remove the screw [3] and pressure/
retraction solenoid /cleaning blade
[1]
[4].
[4]
[2]
[3]
4139F2C583DA
5. Other