Field Service Ver. 1.0 Aug. 2007

Maintenance

2.

Periodic check

2.1

Maintenance procedure (Periodic parts check)

2.1.1

Separator pad

A. Periodically replaced parts/cycle
• Separation pad: Every 50,000 prints
B. Removal procedure
1. Open the top cover.
[2]
[1]
[2]
[1]
[1]
4139F2C641DA
[1]
4139F2C642DA
2. Remove two tabs [1] and separator
cover [2].
3. Remove two screws [1] and the sep-
arator pad [2].
NOTE
• Be extremely careful not to lose the
spring on the separator pad.