Fixed Zoom Change; Factory Test - Konica Minolta magicolor 2590MF Service Manual

Hide thumbs Also See for magicolor 2590MF:
Table of Contents

Advertisement

11. SERVICE MODE

11.10 FIXED ZOOM CHANGE

Function
• The fixed zoom ratios can be changed.
Use
1. Enter the [SERVICE MODE].
Setting/
2. Select [FIXED ZOOM CHANGE] and press the Menu Select key.
procedure
3. Select the fixed zoom ratio that you wish to change and press the Menu Select key.
4. Use the 10-Key Pad to type in the desired fixed zoom ratio.
• Default fixed zoom ratios and setting ranges according to marketing area
<Metric>
Setting name
REDUCTION2
REDUCTION1
EXPANSION1
EXPANSION2
<Inch>
Setting name
REDUCTION2
REDUCTION1
EXPANSION1
EXPANSION2

11.11 FACTORY TEST

• This test is for factory adjustment only and should NOT be used.
SIGNAL TEST
RELAY TEST
SENSOR TEST
DIAL TEST
VOLUME TEST
PANEL BUZZER TEST
RAM TEST
146
Initial fixed zoom ratio
70%
81%
115%
141%
Initial fixed zoom ratio
64%
78%
129%
154%
• This test is for factory adjustment only and should NOT be used.
• This test is for factory adjustment only and should NOT be used.
• This test is for factory adjustment only and should NOT be used.
• This test is for factory adjustment only and should NOT be used.
• To check the volume of the speaker.
• To check the operation of the display and all indicators and buttons.
• When the panel buzzer test are finish, press the panel reset key twice.
• To test reading and writing of the memory.
Field Service Ver. 1.0 Aug. 2007
Setting range
51% to 70%
71% to 99%
101% to 140%
141% to 199%
Setting range
51% to 64%
65% to 99%
101% to 153%
154% to 199%
Functions/Use