Measurement Functions; Engine Test; Multimeter - Bosch FSA 500 Instructions Manual

Vehicle system analysis
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 18
8.10

Measurement functions

8.10.1

Engine test

Measurement functions
Rotational speed
Oil.temp
U-Battery
U-Term. 15
U-Term. 1
Ignition voltage,
spark voltage
Spark duration
Relative compression over starter
current
U-Alternator ripple
I starter
I-Alternator
I-Glow plugs
I-Primary
Dwell angle
Dwell period
Pressure (atmospheric)
Duty cycle
Injection time
Pre-heating time
8.10.2

Multimeter

Measurement functions
Rotational speed
U-Battery
U-Term. 15
U-DC
min./max.
I-1000 A
I-30 A
Resistance
(R-Multi 1)
Pressure P-Air
Pressure P-Fluid
Oil.temp
Air temperature
Diode test
R Test voltage
R Test current
Continuity test
Robert Bosch GmbH
Measuring ranges
Resolution
450 rpm – 6000 rpm
10 rpm
100 rpm – 12000 rpm
10 rpm
250 rpm – 7200 rpm
10 rpm
100 rpm – 500 rpm
10 rpm
-20 °C – 150 °C
0,1 °C
0 – 60 V DC
0.1 V
0 – 60 V DC
0.1 V
0 –10 V
10 mV
0 – 20 V
20 mV
±50 kV
1 kV
±10 kV
0,1 kV
0 – 10 ms
0,01 ms
0 – 200 Ass
0,1 A
0 – 200 %
0.1 %
0 – 1000 A
0.1 A
0 – 30 A
0.1 A
0 – 100 %
0,1 %
0 – 360 °
0,1 °
0 – 50 ms
0,01 ms
50 – 100 ms
0,1 ms
-800 hPa – 1500 hPa
1 mbar
0 – 100 %
0.1 %
0 – 25 ms
0.01 ms
0 – 20 ms
0.01 ms
Measuring ranges
Resolution
as for engine test
0 – 60 V DC
72 mV
0 – 60 V DC
72 mV
±200 mV – ±20 V
0.001 V
±20 V – ±200 V
0.01 V
±1000 A
0.1 A
±30 A
0.01 A
0 – 1000 Ω
0.001 Ω
1 kΩ – 10 kΩ
0.1 Ω
10 kΩ – 999 kΩ
100 Ω
-800 hPa – 1500 hPa
2,5 hPa
0 – 1000 kPa
0,25 kPa
-20 °C – 150 °C
0,2 °C
-20 °C – 100 °C
0,1 °C
max. 4,5 V
max. 2 mA
0 – 10 Ohm
Technical data | FSA 500 | 29 |
Sensors
Connecting cable B+/B–
Clip-on sensor, secondary sensor,
Connecting cable term. 1
30 A amps clamp, diesel clip-on sensor,
1000 A amps clamp (starter current)
Oil temperature sensor
Battery B+/B– cable
Connecting cable term. 15
Connecting cable term. 1
Connection cable term. 1,
Secondary measuring sensor
Connection cable term. 1,
Secondary measuring sensor
Connecting cable term. 1,
Secondary measuring sensor
CH1 multi measurement cable
Amps clamp 1000 A
Amps clamp 30 A
Connecting cable term. 1
Secondary measuring sensor
Amps clamp 30 A
Atmospheric pressure sensor
CH1 / CH2 multi measurement cable
CH1 / CH2 multi measurement cable
CH1 / CH2 multi measurement cable
Sensors
Battery B+/B– cable
Connecting cable term. 15
CH1 / CH2 multi measurement cable
Amps clamp 1000 A
Amps clamp 30 A
CH1 multi measurement cable
Atmospheric pressure sensor
Oil temperature sensor
Air temperature sensor
1 689 989 411
en
|
2023-03-24

Advertisement

Table of Contents
loading

Table of Contents