8.4

Multimeter specifications

R
CH1 zero potential (blue input may be connected to
live measurement points). Input resistance
> 900 kohms.
R
CH2 non-floating (black ground input must be
connected to vehicle ground). Input resistance
> 900 kohms.
8.4.1

DC measurement (CH1 and CH2)

!
Use measuring leads for measurements smaller than
60 VDC, 30 VAC or 42 VACpeak only.
Property
Value/Range
Measuring range
200 mV — 60 V
Accuracy of CH1
±0.75 % of measured value,
plus ±0.25 % of measuring range
Accuracy of CH2
±2 % of measured value,
plus ±0.5 % of measuring range
Resolution
100 µV — 100 mV
(depending on measuring range)
8.4.2
Measurement of AC and rms value
(CH1 and CH2)
*)
Property
AC frequency range
Measuring range
AC accuracy at 100 Hz
rms accuracy at ≤ 100 H
Resolution
The measuring ranges in measurement modes "U" and "I" are
*)
specified as peak-to-peak values. Consequently, the digital
display box is "grayed out" if the set measuring range is briefly
exceeded (overload).
8.4.3

Resistance measurement (CH1)

Property
Measuring range
Accuracy up to 200 K
Accuracy up to 1 M
Resolution
Input resistance
Robert Bosch GmbH
Value/Range
10 Hz — 400 Hz (-3 dB)
200 mV — 30 V
±2 % of measured value, plus
±0.5 % of measuring range
100 µV — 100 mV (depending
on measuring range)
Value/Range
100  — 1 M
±0.75 % of measured value
plus ±0.25 % of measuring
range
±2 % of measured value
plus ±0.25 % of measuring
range
0.1  — 1000 (depending on
measuring range)
> 9 M
Technical data | KTS 340 | 33
8.4.4

Current measurement (CH1 and CH2)

Sensor
Shunt (CH1 only)
30 A clamp (CH1 only)
100 A clamp
600 A clamp
1000 A clamp (CH1 only)
8.4.5

Continuity tester (CH1)

Property
Value/Range
Measurement current
2 mA
No-load voltage
≤ 5 V
Continuity
< 10  (with acoustic check-back)
8.4.6

Diode measurement (CH1)

Property
Value/Range
Measurement current
2 mA
No-load voltage
≤ 5 V
Maximum diode voltage
2 V
8.5

WLAN

Standard: IEEE 802.11g (54 Mbit/s), compatible with
IEEE 802.11b (11 Mbit/s), data encryption: OPEN, WPA,
WPA-PSK, WPA2, WPA2-PSK, WEP (64/128/256 bits),
antenna: -3dBi.
Radio link
KTS 340 to PC/laptop
Workshop environment with clear view
of access point
In vehicle interior with vehicle door or
window open and engine running
The range of the WLAN varies considerably.
20–40 m can normally be achieved indoors and up to
100 m outdoors.
Under adverse conditions the effective range may only
be 10–15 m or even less.
The KTS 340 automatically adapts the transmission
rate in the WLAN to the transmission conditions. In the
event of a poor radio link the data are transmitted
more slowly than with a good link.
en
Measuring range
±600 mA
±30 A
±100 A
±600 A
±1000 A
Minimum range
30 meters
10 meters
|
1 689 989 038