Tx/Rx Function Module Description - ForceDoor BASE70 Instructions And User Manual

Industrial door drive control system
Table of Contents

Advertisement

TX/RX FUNCTION MODULE DESCRIPTION (optional)
1. The external decoding module uses the standard HCS301 format open code, the
frequency 433MHZ/868MHZ is optional,
2. Transmitter 4 button design;Transmitter key value 1, 8, 2, 4
3. The transmitter module and control box use USB standard interface to connect
4. Short press the LEARN button on the module, the LED will light up, press the remote
control to learn the code. Long press the learn button on the module for 6 seconds, LED
will flash 5secondsquickly to clear the code
5. The default maximum number of transmitter storage is 50codes, and if 50 codes
is already learned, the 51
6. Transmitter module function:
a.
Standard function: Single key cycle
b.
Ignore the key value function, all keys are valid: OPEN-STOP-CLOSE
command order each cycle. As long as learning a key, the others are valid
c.
Multiple function key 1:
d. Multiple function key 2:
e.
Multiple function key 3:
7. Adjust the transmitter function through the three-circuit DIP switch
Important Note:
When using multiple function keys, you must use our company's standard transmitter.
The transmitter provided by the customer has inconsistent key values, which may cause
function failure.
st
codewill automatically cover the 1
st
1
button execute OPEN-STOP-CLOSE command order each cycle ;
nd
2
button execute PARTIAL OPEN command order;
rd
3
button execute courtesy light ON/OFF command order;
th
4
button execute remote LOCK command order;
st
1
button execute OPEN the door command order;
nd
2
button execute STOP command order;
rd
3
button execute CLOSE the door command order;
th
4
button execute remote LOCK command order;
st
1
button execute OPEN the door command order;
nd
2
button execute STOP command order;
rd
3
button execute CLOSE the door command order;
th
4
button execute "CF" command order; ("CF"command order means press
th
the 4
button, the door will OPEN directly without STOP action,execute
the REVERSE action during door closing)
st
35
code.

Advertisement