ForceDoor BASE70 Instructions And User Manual page 26

Industrial door drive control system
Table of Contents

Advertisement

FLASH/Warning light
output port setting
Press "+" till "6.-" appears on the
display.
Press SET then appears "6.0" on the
display
Press "+" till "6.3" appears on the
display.
Press SET enter into the Electronic
lock function setting.
Electronic lock function is off
(default)
Electronic lock function is enabled:
1 second after the door drive runs to the
close limit position, the electronic lock
is powered on, the bolt is pushed out,
and after 1.5 seconds electronic lock
stops supplying power.
After the door drive receives the door
opening command at the close limit
position, the electronic lock will be
powered on firstly to retract the bolt,
then the door starts to run after 1.5
seconds, and the electronic lock stops
power supply after the door runs for 1
second.
Remark:
The default electronic lock function is
off.
Press and hold SET button for about
6 seconds to enter main menu until
"0.-" appears on the display then
release the button.
Press "+" till "6.-" appears on the
display.
Press SET then appears "6.0" on the
display
Press "+" till "6.4" appears on the
display.
Press SET enter into the FLASH/
Warning light output port setting.
Warning light flashes when the door is
running, and warning light off when the
door is stop. (default)
24