XH06-2 Relay output
module function setting
time setting. Adjust the stalls from
to
means: 10 minutes;
Represents 3 minutes
The relay is closed during door drive
operation.
When the door drive running, the relay
flashes at a frequency of 1HZ (externally
extended warning light function)
Relay no action
Remark:
default.
The customer can set the function according
to the specific use situation and choose the
appropriate function with the normally open
(NO) and normally closed (NC) function of
the relay.
Press and hold SET button for about 6
seconds to enter main menu until "0.-"
appears on the display then release the
button.
Press "+" till "6.-" appears on the
display.
Press SET then appears "6.0" on the
display
Press "+" till "6.7" appears on the
display.
Press SET enter into XH06-2 Relay
output module function setting. (Refer
to page - 36 Relay module output
terminal)
Reach the open limit position, relay closed
Reach the close limit position, relay closed
27
by buttons +/-. A=10.