Sm3000 Smart Meter Diagnostics - Redback ST10000 Owner's Manual

Smart 3-phase hybrid system
Table of Contents

Advertisement

Name
Icon &
Pattern
SOLAR
GRID
NETWORK

SM3000 Smart Meter diagnostics

The Redback SM3000 Smart Meter is usually located at the main switchboard. It
detects the grid energy traffic of all 3 phases and indicates if the site overall is
importing or exporting energy to the grid. This information informs inverter operation.
Name
Colour &
Pattern
Power
Energy
Flow
Comm's
Meaning and or
Solution(s)
probable cause
Solar is active
Solar is disconnected or
not active
Grid is active
Grid not detected
Wi-Fi, LAN or BT is
connected
No Wi-Fi, LAN or BT
connected
Meaning
ON: Meter has power.
OFF: Meter does not have power or has failed.
ON: Site is consuming energy from the grid.
Flashing: Site is exporting energy to the grid.
OFF: Energy flow is not detectable.
Flashing: Transmitting data.
5x Flash: Reset in progress.
OK. No action required.
Ensure the PV ARRAY DC isolator in
ON. Contact your installer if this is
unexpected behaviour.
No action required.
Normal behaviour during a Grid
outage.
If grid is available: Switch UTILITY
GRID AC isolators on.
No action required.
Onboard the inverter.