Redback ST10000 Owner's Manual page 30

Smart 3-phase hybrid system
Table of Contents

Advertisement

Specifications
ISOLATORS
Manufacturer Part Number
Rated Insulation Voltage
Rated Impulse Withstand Voltage
Suitability for Isolation
Rated Operational Current
Utilisation Category
Rated Short-time Withstand Current (Icw)
Rated Short-ciruit Making Capacity (Icm)
Rated Breaking Capacity (Isc)
COMMUNICATIONS PORTS AND PROTOCOLS
Ethernet
DRED
Relays
kWh Meter
RS485
Wi-Fi
LTE
Interlock
USER INTERFACE
Front Panel Display
Communications
Remote Access
Power/Energy Monitoring
CERTIFICATIONS AND APPROVALS
AS/NZS 4777.2:2020
IEC 62109-1:2010
IEC62109-2:2011
DESIGNED WITH INSTALLATION STANDARDS CONSIDERED
AS/NZS 3000:2018
30
Owner's Guide – Redback ST10000 and BE14000-HV – v1.6
PV
PORT
XBE+3610
1100V
8kV
C
16A
DC-PV2
700A
1000A
5kA
RJ45; Straight-thru
RJ45; DRED
RJ45; 3x Ditial I/O; +DC5V & GND
RJ45; RS485 MODBUS
RJ45; Factory Use Only
802.11b/g/n/ac; 2.4GHz
na
na
Coded, coloured LEDs
Bluetooth for commissioning; Wi-Fi or ethernet for remote access
Web Portal; MYRedback app
Includes 1 x utility grade energy meter (class 1)
IEC 62116:2014
IEC 62040-1:2017
IEC 62477-1:2012
AS/NZS 5139:2019
GRID
BACKUP
INTERACTIVE
PORT
PORT
S203-C40
S203-C25
440V
440V
4kV
4kV
C
40A
25A
A
A
-
-
15kA
15kA
IEC 60529
EN 61000
AS/NZS 5033:2014 (inc. Amd 1 & 2)
BATTERY
PORT
S802PV-SP32
DC1500V
8kV
C
C
32A
A
-
-
-
-
5kA
RCM
CE Mark (LVD, EMC, RoHS directives)
BATTERY
CABINET
NoArk Ex9BP
DC1000V
4kV
C
32A
A
-
-
10kA

Advertisement

Table of Contents
loading

This manual is also suitable for:

Be14000-hv

Table of Contents