Diagnostics

Your Redback Inverter is equipped with a LED arrays to indicate system status and aid diagnosis.
Inverter LEDs (SH4600 and SH5000)
Name
Colour/pattern
System Ready
Solar Array
Utility Grid
Energy Flow
System Error
Backup Power
Storage Battery
Communications
Redback Technologies
Audience: Home owner Installer .
Meaning
ON: System ready
BLINK: System Starting up
OFF: System is not operating
Solar Input #1
Solar Input #2
Active
Active
Active
Inactive
Inactive
Active
Inactive
Inactive
ON: Grid Active and connected
BLINK: Grid is active but not connected
OFF: Grid is not active
ON: Consuming energy from grid / buying
BLINK: Supplying energy to grid / zeroing
BLINK 2: Supplying energy to grid / selling
OFF: Grid not connected or system not operating
ON: Fault has occurred
BLINK: Overload of backup output / reduce load
OFF: No fault
ON: Backup is ready/ power available
OFF: Backup is off / no power available
ON: Battery is charging
BLINK: Battery is discharging
BLINK 2: Battery is low / SOC is low
OFF: Battery is disconnected / not active
ON: Online
BLINK: Local connection only (no internet)
OFF: Not connected
Ouija LEDs (visible on SH5000 only)
Name
Colour/pattern
Meaning
Power
ON: The Ouija Board is powered up
OFF: The Ouija Board is shut down
Heartbeat
BLINK: The Ouija Board software is operational
OFF: The Ouija Board software is updating or not operational
Inverter
BLINK: Inverter settings are being applied
ON: The Ouija Board is connected to the Inverter (internal)
OFF: The Ouija Board is not connected to the Inverter (internal)
Battery
BLINK: The Inverter is not accepting battery information from the Ouija
ON: The Ouija Board is connected to battery and BMS is communicating
OFF: Battery is disconnected or the Ouija & BMS are not communicating
Wi-Fi
BLINK: Inverter Wi-Fi is in hotspot mode (discoverable)
ON: Inverter is connected to the network via Wi-Fi or Ethernet
OFF: Inverter is not connected to the network
4G
OFF: Not used
GUI- 003 Knowledge Base- Resetting your Redback Inverter
Version 1.0 - 27/07/2018 - Page 4 of 16