Cleaning the BE14000-HV fan filters

Occasionally, it is necessary to clean the battery enclosure filters and filter covers. There are four filters in total, two at each
side of the enclosure. To clean the filters:
1.
Switch the Battery Enclosure Isolators OFF (right)
2.
Switch BATTERY SYSTEM DC isolator OFF (down).
3.
Fans are installed in the upper vents only and will operate if the batteries
are hot. Ensure the fans are off before accessing the upper vents. While
waiting, you can start work on the lower vents.
4.
Using a small screwdriver or similar tool, pry the filter covers from the
filter baskets- there are two pry points at the lower edge of the cover.
5.
Brush, wipe or vacuum any dust or debris from the covers.
6.
Remove the filters from the baskets. Wash in cold soapy water, rinse and
squeeze out excess water. Lay flat to dry.
7.
Inspect the fan blades. Remove heavy dust build-up with a brush, cloth, or
vacuum cleaner. Do not use fluids of any type.
8.
Refit the filters to the baskets.
9.
Refit the filter covers, ensuring the vents face downward. There should be
two tactile "clicks" as the snap-fits engage.
10.
Switch the Battery Enclosure Isolators OFF (left)
11.
Switch the BATTERY SYSTEM DC isolator ON (up).
Owner's Guide – Redback ST10000 and BE14 000-HV - v1.6