Side wall clearances are 7". Combustible surrounds may be installed
with 7" clearance to the edge of the opening as shown.
Combustible surround is permissible flush to opening when the
chase is vented AND fireplace venting ports are opened.
TOP OF UNIT
Figure 17.b Sidewall clearances
NOTICE
7" clearance in sidewall drawing does not apply to recession, unit
cannot be recessed into a wall.

Finishing Safety Zone

Take special care when finishing underneath the fireplace door due to
the location of the gas valve and control board. Any screw can possibly
puncture one of these components resulting in either a non operational
unit or worse, a gas leak.
1" screw
safe zone
XG0232 - 043021
Edge of opening
Sidewall
7"
Min.
1" screw
safe zone
WARNING
The use of the fans when the Cool Wall Release OR Cool Wall
Advantage system is used will result in significantly higher wall
temperatures. These higher temperatures can negatively impact
the finished wall surface, art, and or mounted TV. Therefore,
Montigo STRONGLY RECOMMENDS that fans be disconnected
when the Cool Wall Release OR Cool Wall Advantage system is used.
This can be done through the remote control (See instructions)
or by disconnecting the fan harness. Montigo is NOT responsible
for damage to facing materials, and items placed above the
fireplace (eg. TV, artwork)

FULL LOAD VERSIONS:

Disable fans via remote
1. Turn the fireplace on, turn fans to off setting.
2. Partially take out one battery.
3. Hold both the Mode AND On/Off button.
4. Insert battery (while still holding the two
buttons), then release Mode button (keep
On/Off pressed).
5. Cycle through modes with Mode button until
you get to fan setting, with Down button set
fan function from Set to Clr.
6. Release On/Off button, turn the fireplace on.
There will be now be no fan mode on remote.