WARNING
The use of the fans when the Cool Wall Release OR Cool Wall
Advantage system is used will result in significantly higher wall
temperatures. These higher temperatures can negatively impact
the finished wall surface, art, and or mounted TV. Therefore,
Montigo STRONGLY RECOMMENDS that fans be disconnected
when the Cool Wall Release OR Cool Wall Advantage system is used.
This can be done through the remote control (See instructions)
or by disconnecting the fan harness. Montigo is NOT responsible
for damage to facing materials, and items placed above the
fireplace (eg. TV, artwork)

FULL LOAD VERSIONS:

Disable fans via remote
1. Turn the fireplace on, turn fans to off setting.
2. Partially take out one battery.
3. Hold both the Mode AND On/Off button.
4. Insert battery (while still holding the two
buttons), then release Mode button (keep
On/Off pressed).
5. Cycle through modes with Mode button until
you get to fan setting, with Down button set
fan function from Set to Clr.
6. Release On/Off button, turn the fireplace on.
There will be now be no fan mode on remote.
BASIC VERSIONS (IF OPTIONAL
FAN KIT ALREADY INSTALLED):
Disable fans via harness
1. Unplug the fan
harness that
connects power to
the speed control.
XG0226 - 042220

Section 3: Venting

Montigo offers a variety of direct venting and termination options. The
direct vent termination location MUST be selected such that it is the
highest point in the venting assembly. It should also be selected such
that it provides the shortest vent run possible. Should it be impossible
to ensure that the termination is the highest point or to meet the
venting guidelines laid out below please contact your Montigo dealer
to discuss power venting options.
Notes For Planning Venting:
• Venting originates from the top of the unit
• Venting can terminate through the roof or through an exterior wall.
• Refer to Appendix A - Termination Locations to ensure the planned
termination location is acceptable.
• Once the termination location has been established, refer to the
appropriate section below for installation details
• All fireplaces shipped from the factory are top vent.
• Silicone application is NOT required when joining Montigo vent
pipes and components.
NOTICE
Under no circumstances can Montigo flex venting be cut to accommodate
an installation. Use an alternative length to complete your vent run.
(Excluding flex included in the MVK05 / MVK05F / PVK05 / PVK05F)
FLEXMASTER VENT KITS -
Flexmaster venting kits are prepackaged sets of flex venting,
wall shields, and terminations. The flex is collarless and must
be milpacked and screwed. These kits are approved for all 4/7
and 5/8 fireplaces though cannot be used when the unit is
powervented.
Figure 4.a MVK05 / MVK05F Flex Vent Kit
Installation
19