Montigo C34DV Installation & Maintenance Manual

Montigo C34DV Installation & Maintenance Manual

C-series dv gas fireplace

Advertisement

C-Series DV Gas Fireplace
C38DV Indoor Shown
Warning:
Improper installation, adjustment, alteration, service or maintenance can cause
injury or property damage. Refer to this manual. For assistance or additional
information consult a qualified installer, service agency or the gas supplier.

Safety Notice:

Glass doors on gas fireplaces are extremely hot while the fireplace is on and remain
hot even after the fireplace has been turned off. Safety screens are available and
can reduce the risks of severe burns. Please keep children away from the fireplace
at all times.

For Your Safety:

Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
XG0170
Installation Operation & Maintenance Manual
Check local codes and read all instructions prior to installation.
®
C
US
Canadian Heating Products Inc. Langley, BC V4W 4A
www.montigo.com
C34DV
C38DV
Warning:
mation in these instructions is not
followed exactly, a fire or explosion
may result causing property dam-
age, personal injury or death.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical
switch; do not use any phone in
your building.
Immediately call your gas
supplier from a neighbor's
phone. Follow the gas supplier's
instructions.
If you cannot reach your gas
supplier, call the fire department.
Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
Montigo Del Ray Corp. Ferndale, WA 98248
Indoor
Indoor
If the infor-
Installer: Leave this manual
with the appliance.
Consumer: Retain this
manual for future reference.
080610

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the C34DV and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Montigo C34DV

  • Page 1: Safety Notice

    • Installer: Leave this manual with the appliance. • Consumer: Retain this ® manual for future reference. XG0170 Canadian Heating Products Inc. Langley, BC V4W 4A Montigo Del Ray Corp. Ferndale, WA 98248 080610...
  • Page 2: Table Of Contents

    Installation, Your new Montigo gas fireplace will give you years of durable, Operations and Maintenance manual. Pay special attention to all reliable use. Welcome to the Montigo family of gas fireplace cautions, warnings, and Important warnings.
  • Page 3: Introduction

    Standard Log Set Montigo in combination with this Montigo fireplace system. The C34DV is rated for Natural Gas at 20,000 BTU/H (5.86 Installation other than as instructed in this manual. Kilowatts) Input or Propane at 20,000 BTU/H (5.86 Kilowatts) Input.
  • Page 4: Installation

    C-Series DV Gas Fireplace Installation Installing and Framing the Fireplace Framing * When sheetrock is The fireplace may be installed in any location that maintains proper clear- not used behind the ances to air conditioning ducts, electrical wiring and plumbing. Safety, fireplace, framing depth may be reduced as well as efficiency of operation, must be considered when selecting...
  • Page 5: Installing The Gasline

    Vent terminations can be very hot. If the termination is less than 7 feet  bubbling stops completely or leak is no longer detected. above a public walkway, it should be fitted with a certified Montigo DO NOT use a flame of any kind to test for leaks. Heat Guard. (Part no. PTKOG).
  • Page 6: The Remote Switch

    C-Series DV Gas Fireplace Installation Installing Terminations with Built-In Frames Installing Heat Guards over Terminations MTO-3F (4"/7") PTO-3F (5"/8") MTKOG (4"/7") PTKOG (5"/8") Ensure that the two long mounting brackets are facing the bottom Frame the termination opening to 11" x 11". of the termination.
  • Page 7: Top Vent Venting Runs

    C-Series DV Gas Fireplace Installation Top Vent Venting Runs Installation of Rear Vent DV For the C-Series DV Top Vent, there are two types of installations: The following venting components are available for the Rear Vent A) Through-The-Wall Installations and B) Vertical (Through-The-Roof) installation: Installations.
  • Page 8 C-Series DV Gas Fireplace Installation Example 1: For our shortest venting configuration use components A and E (see table on page 6). PEL-90F/F Elbow Figure 12. Extended Installation using a combination of solid and flex venting. Use the vent graph to determine your allowable run, then select appropriate components.
  • Page 9 C-Series DV Gas Fireplace Installation B. Vertical (Through-The-Roof) Installations A maximum of two offsets (each offset has two 90° bends) may be  made and shall not exceed total length of 25% of the vertical vent Vertical rise > 12' can be reduced ...
  • Page 10: Rear Vent Venting Runs

    C-Series DV Gas Fireplace Installation Reduced Vertical Installation 2. 45° Corner Installation. Attach an PEL-45 (45° elbow) directly onto the flue collar. Cut the It is possible to reduce vertical vent runs from 5"/8" venting to 4"/7" venting. Reduced vertical venting may only be used when the installation PXT-20 to suit, and attach it to the PEL-45.
  • Page 11 C-Series DV Gas Fireplace Installation Installation Of Rear Vent DV B. Multi-Elbow Installations For more difficult installation situations, the C-Series DR Rear Vent may The following venting components are available for an C-Series DV in be installed with two - 90° elbows and up to 15' of horizontal run. If using a Rear Vent installation: this installation option, you must adhere to the following guidelines: 5"...
  • Page 12: Finishing Around The Fireplace

    Alkyd sealer prior to the applying of latex paints. This is to prevent leaching of water from evaporation and causing a brownish staining effect to paint over coats. Figure 24. Combustible mantles and facings for C34DV. C38DV Figure 25. Combustible surrounds.
  • Page 13: Wiring

    C-Series DV Gas Fireplace Installation Wiring Wiring for the optional Fan Kit All C-Series DV fireplaces may be equipped with optional fan kits for circulating heat into the living space. Gas Control and Pilot Wiring C-Series DV-I Installations in Canada which employ the fans must be electrically grounded in accordance with CSA C22.1 Canadian Electrical Code Honeywell (Q3450) Pilot Assembly...
  • Page 14 C-Series DV Gas Fireplace Installation Gas Control and Pilot Wiring C-Series DV-F Figure 27. Wiring for the SIT IPI Wiring Schematic CAUTIONS! DO NOT OPERATE THIS FIREPLACE WITHOUT THE GLASS DOOR OR WITH A BROKEN GLASS DOOR. Page 14 Part No. XG0170 - 080610...
  • Page 15: Removing And Installing The Door

    (See figure 29) Install the upper trim pieces so that the baffle is resting between the top and middle piece, as shown below. The trim piece with the Montigo Emblem should be installed on the lower middle clips with the emblem on the right side.
  • Page 16: Positioning The Logset

    C-Series DV Gas Fireplace Installation Installing the Log Set Installing the Logs: The C-Series DV is supplied with five ceramic fibre logs. Unpack the logs and handle them very carefully. Remove the door cover and the glass door. Place the Back log onto the back log rest as shown below in figure 24a.
  • Page 17: Operation

    C-Series DV Gas Fireplace Operation - Model C-Series DV C-Series DV with Continuous Pilot For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A.
  • Page 18: Lighting Instructions

    C-Series DV Gas Fireplace Operation - Model C-Series DV-I C-Series DV-I with Honeywell Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A.
  • Page 19 C-Series DV Gas Fireplace Operation - Model C-Series DV-F C-Series DV-F Proflame SIT Electronic Ignition with American Flame Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING! If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 20: Operation

    C-Series DV Gas Fireplace Operation Maintenance Lighting Instructions General Have the fireplace and installation inspected yearly. The inspection See pages 17 to 19. ■ must include, but is not limited to, the following: Burner Adjustment C-Series DV • A visual check of the entire vent system and termination. The C-Series DV is equipped with an adjustable burner, allowing you •...
  • Page 21: Gas Control Valve

    C-Series DV Gas Fireplace Maintenance Gas Control Valve Troubleshooting C-Series-DV The following is a troubleshooting chart of possible problems: PROBLEM CORRECTIVE ACTION Noisy Pilot Flame Locate pilot adjustment screw on gas control valve. Flame is decreased by turning adjustment screw clockwise. Pilot won’t ignite Disconnect remote wires and try to (Shown in "Pilot"...
  • Page 22: Spare Parts

    C-Series DV Gas Fireplace Maintenance Notes Spare Parts - C-Series DV C34DV C38DV RGC1006 RGC1006 NG Gas Valve LP Gas Valve RGC1005 RGC1005 NG Pilot RPA020 RPA020 LP Pilot RPA021 RPA021 Burner NG Front RBT1005 RBT1009 Burner NG Rear RBT1006...
  • Page 23: Warranty

    The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.
  • Page 24: Termination Locations

    C-Series DV Gas Fireplace Appendix A - Termination Locations A = clearance to the termination frame above grade, veranda, porch, deck, clearance above paved sidewalk or a paved driveway located on public † or balcony [16 inches (41 cm) minimum] property [*7 feet (2.1 m) minimum] B = clearance to door, or sides and top of window, that may be opened [16 P = c l e a r a n c e u n d e r v e r a n d a , p o r c h , d e c k , o r b a l c o n y...
  • Page 25: B State Of Massachusetts / Amendment

    C-Series DV Gas Fireplace Appendix B - State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as follows: Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manually reset device that will automatically shut off the gas to the burner in the event of a sustained back-draft (2) Revise 10.8.3 by adding the following additional requirements:...
  • Page 26: Notes

    C-Series DV Gas Fireplace Notes Page 26 Part No. XG0170 - 080610...
  • Page 27 C-Series DV Gas Fireplace Notes Page 27 Part No. XG0170 - 080610...
  • Page 28 XG0170 - 080610 Montigo Del Ray Corp. Canadian Heating Products Inc. Ferndale, WA 98248 Langley, BC V4W 4A1...