Certification
6.2 EMC and Environmental Type Tests
EMC Type Tests per IEC 61850-3
Note
In the case of an all fiber port configuration, this product meets all Class 2 re-
quirements. Otherwise, all Class 1 requirements are met for copper ports.
If the unit contains copper ports, the IEC 1613 conformance is Class 1, during
which disturbance errors may occur but recovery is automatic.
If the unit contains all fiber ports, the IEC 1613 conformance is Class 2, during
which no disturbance errors will occur.
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
IEC 61000-4-12
IEC 61000-4-16
36
All manuals and user guides at all-guides.com
Test
ESD
Radiated RFI
Burst (Fast
Transient)
Surge
Induced (Con-
ducted) RFI
Magnetic Field
Voltage Dips
and Interrupts
Damped
Oscillatory
Mains Frequen-
cy Voltage
Description
Enclosure Contact
Enclosure Air
Enclosure Ports
Signal Ports
DC Power Ports
AC Power Ports
Earth Ground Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Earth Ground Ports
Enclosure Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
AC and DC
Power Ports
Test Levels
Severity Levels
±8 kV
±15 kV
20 V/m
±4 kV @ 2.5 kHz
±4 kV
±4 kV Line-to-
Ground, ±2 kV
Line-to-Line
±2 kV Line-to-
Ground, ±1 kV
Line-to-Line
±4 kV Line-to-
Ground, ±2 kV
Line-to-Line
10 V
100 A/m
Continuous
1000 A/m for 1 s
30% for 1 period
60% for 50 periods
100% for 5 periods
100% for
50 periods
2.5 kV Common
1 kV Differential
Mode @1 MHz
30 V Continuous
300 V for 1s
RUGGEDCOM M2100F