6. THE SETTINGS MENU
• USB AUDIO/MIDI
Sets the Analog Heat +FX to send and receive audio and MIDI over USB. Select this option if you
want to use the Analog Heat +FX together with a class compliant USB audio host. For more infor-
mation, please see "5.15 CLASS COMPLIANT DEVICE" on page 16. (ON, OFF)

6.8.2 OS UPGRADE

Use this menu option when you want to upgrade the Analog Heat +FX OS. To send the OS syx file, use
our free Elektron Transfer software. The OS syx file and Elektron Transfer can be downloaded from the
Elektron website.
For the transfer to be possible, the device sending the OS syx file must be connected to the USB port of
Analog Heat +FX OS.
Please note that the Analog Heat +FX OS will not appear as an icon on your computer desktop.
1. Connect the Elektron device to the computer via USB.
2. Open the Transfer application on your computer.
3. On the Transfer CONNECTIONS page, set the MIDI IN and MIDI OUT ports to your Elektron device.
4. On the Transfer DROP page, drag and drop the OS file. The OS file is then automatically trans-
ferred to the Elektron device and the OS update initiates. A progress bar is visible on device screen
when receiving the OS.
5. On your device. Press [YES] to confirm the OS update.
When the process is successfully completed, the OS is updated and the unit reboots.

6.8.3 CALIBRATION

CALIBRATION starts the calibration routine for the drive circuits and filters. After selecting this option,
a popup window appears asking to confirm the calibration. Press [YES] to proceed with the calibration.
Please note that the calibration routine takes quite a while to complete.
The device should be turned on for at least 2 hours before you perform a calibration for
its circuits to warm up properly. If the unit has not yet warmed up for 2 hours, there is a
calibration countdown counter which automatically initiates the calibration once it reaches
the timeout.
Also, please note that nothing should be connected to the device during the calibration.
Analog Heat +FX is factory calibrated. It should not be re-calibrated unless specifically
stated by Elektron Support or if prompted by the machine.