Unpacking - Procom MN200EPC Owner's Operation And Installation Manual

Infrared vent-free natural gas space heater
Table of Contents

Advertisement

Burners
Lower Front Panel
LOCAL CODES
CONTINUED
Install and use heater with care. Follow all local
codes. In the absence of local codes, use the
latest edition of National Fuel Gas code ANSI
Z223.1, also known as NFPA 54*.
*Available from :
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
1 Batterymarch Park
Quincy, MA 02269 -9101
WATER VAPOR: A BY-PRODUCT OF UNVEN-FREE ROOM HEATERS
Water vaporis a by-product of gas combustion. An vent-
free room heater produces approximately one (1) ounce
(30ml) of water for every 1,000 BTU's (.3KW 's) of gas
input per hour.
Unvented room heaters are intended for as supplemental
heat (a room) rather than a primary heat source (an entire
house). In most supplemental heat application, the water
vapor does not create a problem. In most applications,
the water vapor enhances the low humidity atmosphere
experience during cold weather.
The following steps will help insure that water vapor does
not become a problem.
1. Be sure the heater is sized properly for the application,
including ample combustion and ventilation air.
PRODUCT FEATURES
Touch Pad
ON/OFF Switch
Safety Pilot
Figure1 Vent-Free Heater
Cabinet Top
Grill Guard
Ignitor
System
Control Knob
Control System
State of Massachusetts : The installation must be
made by a licensed plumber or gas fitter in the Com-
monwealth of Massachusetts.
Sellers of unvented propane or natural gas-fired
supplemental room heaters shall provide to each
purchaser a copy of 527 CMR30 upon sale of the
unit.
In the State of Massachusetts,unvented propane and
natural gas-fired space heaters shall be prohibited
in bedrooms and bathrooms.

UNPACKING

1. Remove heater from carton.
2. Remove all protective packaging applied to
heater for shipment.
3. Check heater for any shipping damage. If heater
is damaged. promptly inform dealer where you
bought heater.
2. If high humidity is experienced, a dehumidifier
may be used to help lower the water vapor content
of the air.
3. Do not use a vent-free room heater as the primary
heat source.
IMPORTANT: Vent-free heaters add mois-
ture to
the air. Although this is beneficial,
installing heater in rooms
ventilation air may cause mildew to form from
too much moisture. See Fresh Air for Combus-
tion and Ventilation, pages 5 and 6.
4
for Manual Override Control
Door
for Manual Override
without enough

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MN200EPC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Mn200ehpcMn300epcMn300ehpc

Table of Contents